Measurement of cochlear implant electrode position from intraoperative post-insertion skull radiographs: a validation study

M Svrakic, DR Friedmann, PM Berman… - Otology & …, 2015 - journals.lww.com
Objective: To validate a method of measuring angular depth of insertion (aDOI) as well as
positional depth of each electrode contact in a cochlear implant by using intraoperative …

Intracochlear electrocochleography: Influence of scalar position of the cochlear implant electrode on postinsertion results

WJ Riggs, RT Dwyer, JT Holder, JK Mattingly… - Otology & …, 2019 - journals.lww.com
Background: Translocation of the CI electrode from ST into SV can limit performance
postoperatively. ECochG markers of trauma may be able to aid in the ability to detect …

Cone beam CT for perioperative imaging in hearing preservation Cochlear implantation–a human cadaveric study

K Nateghifard, D Low, L Awofala… - … -Head & Neck …, 2019 - journals.sagepub.com
Background Knowledge of the cochlear implant array's precise position is important
because of the correlation between electrode position and speech understanding. Several …

The value of digital volume tomography in assessing the position of cochlear implant arrays in temporal bone specimens

T Kurzweg, CV Dalchow, M Bremke, O Majdani… - Ear and …, 2010 - journals.lww.com
Objectives: Radiological evaluation of the position of cochlear implant (CI) devices is an
upcoming method for quality control after CI surgery. First, results of imaging of the middle …

Digital imaging: a valuable technique for the postoperative assessment of cochlear implantation

JT Lawson, K Cranley, JG Toner - European Radiology, 1998 - Springer
Cochlear implantation with a multi-channel electrode array which provides stimulation via
the auditory nerve has become a standard treatment for profound deafness. Postoperative …

Another reason for intra-operative imaging during cochlear implantation

M Viccaro, E De Seta, E Covelli, V Marvaso… - The Journal of …, 2008 - cambridge.org
Objective: We report a case of a rare cochlear implant complication: the introduction of the
electrode array into the superior semicircular canal, with intra-operative measurements of …

[PDF][PDF] Cochlear implant electrode array insertion monitoring with intra-operative 3D rotational X-ray

B Carelsen, W Grolman, R Tange, GJ Streekstra… - Clin …, 2007 - academia.edu
Results We have been using the 3D-RX scanning system since February 2005 in every
cochlear implantation. Twentythree patients have been scanned according to the procedure …

[PDF][PDF] In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays

DR Ketten, MW Skinner, GE Wang… - ANNALS OF …, 1998 - academia.edu
Three-dimensional cochlear canal lengths, electrode array intracochlear insertion depths,
and characteristic frequency ranges were estimated for 20 Nucleus implant recipients on the …

Automatic electrode scalar location assessment after cochlear implantation using a novel imaging software

S Geiger, M Iso-Mustajärvi, T Nauwelaers, E Avci… - Scientific Reports, 2023 - nature.com
As of today, image-based assessment of cochlear implant electrode array location is not part
of the clinical routine. Low resolution and contrast of computer tomography (CT) imaging, as …

Temporal bone microdissection for anatomic study of cochlear implant electrodes

CG Wright, PS Roland - Cochlear Implants International, 2005 - Taylor & Francis
Objective This report describes a temporal bone microdissection method for laboratory
evaluation of cochlear implant electrodes. Design Anatomic study of human temporal bones …