Optimized 3D ultrashort echo time pulmonary MRI
Purpose To optimize 3D radial ultrashort echo time MRI for high resolution whole‐lung
imaging. Methods 3D radial ultrashort echo time was implemented on a 3T scanner to …
imaging. Methods 3D radial ultrashort echo time was implemented on a 3T scanner to …
Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study
Objective To determine the feasibility of using high-resolution volumetric zero echo time
(ZTE) sequence in routine lung magnetic resonance imaging (MRI) and compare free …
(ZTE) sequence in routine lung magnetic resonance imaging (MRI) and compare free …
Oxygen‐enhanced 3D radial ultrashort echo time magnetic resonance imaging in the healthy human lung
The purpose of this work was to use 3D radial ultrashort echo time (UTE) MRI to perform
whole‐lung oxygen‐enhanced (OE) imaging in humans. Eight healthy human subjects …
whole‐lung oxygen‐enhanced (OE) imaging in humans. Eight healthy human subjects …
Ultrashort echo time (UTE) MRI of the lung: assessment of tissue density in the lung parenchyma
O Togao, R Tsuji, Y Ohno, I Dimitrov… - Magnetic resonance …, 2010 - Wiley Online Library
Nonuniform disruption of lung architecture is usually assessed by CT, which carries potential
radiation risk. Here we report our use of a three‐dimensional ultrashort echo time MR …
radiation risk. Here we report our use of a three‐dimensional ultrashort echo time MR …
Structure-function imaging of lung disease using ultrashort echo time MRI
Rationale and Objectives: The purpose of this review is to acquaint the reader with recent
advances in ultrashort echo time (UTE) magnetic resonance imaging (MRI) of the lung and …
advances in ultrashort echo time (UTE) magnetic resonance imaging (MRI) of the lung and …
[HTML][HTML] Outracing lung signal decay–potential of ultrashort echo time MRI
MO Wielpütz, SMF Triphan, Y Ohno… - RöFo-Fortschritte auf …, 2019 - thieme-connect.com
Background Magnetic resonance imaging (MRI) of the pulmonary parenchyma is generally
hampered by multiple challenges related to patient respiratory-and circulation-related …
hampered by multiple challenges related to patient respiratory-and circulation-related …
Free-breathing, zero-TE MR lung imaging
Object The investigation of three-dimensional radial, zero-echo time (TE) imaging for high-
resolution, free-breathing magnetic resonance (MR) lung imaging using prospective and …
resolution, free-breathing magnetic resonance (MR) lung imaging using prospective and …
Lung MRI at 1.5 and 3 Tesla: observer preference study and lesion contrast using five different pulse sequences
C Fink, M Puderbach, J Biederer, M Fabel… - Investigative …, 2007 - journals.lww.com
Objectives: To compare the image quality and lesion contrast of lung MRI using 5 different
pulse sequences at 1.5 T and 3 T. Materials and Methods: Lung MRI was performed at 1.5 T …
pulse sequences at 1.5 T and 3 T. Materials and Methods: Lung MRI was performed at 1.5 T …
Pulmonary MRI of neonates in the intensive care unit using 3D ultrashort echo time and a small footprint MRI system
Purpose To determine the feasibility of pulmonary magnetic resonance imaging (MRI) of
neonatal lung structures enabled by combining two novel technologies: first, a 3D radial …
neonatal lung structures enabled by combining two novel technologies: first, a 3D radial …
Ultra‐short echo time (UTE) MR imaging of the lung: comparison between normal and emphysematous lungs in mutant mice
M Takahashi, O Togao, M Obara… - Journal of magnetic …, 2010 - Wiley Online Library
Purpose: To investigate the utility of ultra‐short echo time (UTE) sequence as pulmonary
MRI to detect non‐uniform disruption of lung architecture that is typical of emphysema …
MRI to detect non‐uniform disruption of lung architecture that is typical of emphysema …