Reduction in intraocular pressure after laser in situ keratomileusis

HJ Park, KB Uhm, C Hong - Journal of Cataract & Refractive Surgery, 2001 - Elsevier
PURPOSE: To investigate whether intraocular pressure (IOP) measured on the nasal side is
affected after laser in situ keratomileusis (LASIK). SETTING: The Glaucoma Service, Dr …

Changes in intraocular pressure after laser in situ keratomileusis

KM Rashad, AA Bahnassy - Journal of refractive surgery, 2001 - journals.healio.com
ABSTRACT PURPOSE: To evaluate changes in intraocular pressure (IOP) measurements
by Goldmann applanation tonometry after laser in situ keratomileusis (LASIK) for myopia …

Underestimation of intraocular pressure in eyes after laser in situ keratomileusis

A Arimoto, K Shimizu, N Shoji, K Enomoto… - Japanese journal of …, 2002 - Elsevier
Purpose: Retrospectively, we reviewed the records of 65 patients (115 eyes) regarding the
intraocular pressure (IOP) after laser in situ keratomileusis (LASIK). Methods: The mean …

Intraocular pressure assessment in both eyes of the same patient after laser in situ keratomileusis

SY Hsu, MS Chang, CJ Lee - Journal of Cataract & Refractive Surgery, 2009 - Elsevier
PURPOSE: To measure intraocular pressure (IOP) after laser in situ keratomileusis (LASIK)
in both eyes of the same patient and analyze the correlation between IOP measurement and …

Intraocular pressure change measured by Goldmann tonometry after laser in situ keratomileusis

AV Fournier, M Podtetenev, J Lemire… - Journal of Cataract & …, 1998 - Elsevier
Purpose: To assess the accuracy of Goldmann tonometry after laser in situ keratomileusis
(LASIK). Setting: University-based refractive surgery group (Clinique du Laser Visuel) …

Change in intraocular pressure in myopic eyes measured with contact and non-contact tonometers after laser in situ keratomileusis

MA El Danasoury, A El Maghraby… - Journal of refractive …, 2001 - journals.healio.com
ABSTRACT PURPOSE: To study the change in the intraocular pressure (IOP) after laser in
situ keratomileusis (LASIK) for correction of myopia. METHODS: One hundred twenty …

Changes in intraocular pressure after laser in situ keratomileusis for myopia, hyperopia, and astigmatism

LM Agudelo, CA Molina… - Journal of refractive …, 2002 - journals.healio.com
ABSTRACT PURPOSE: Reports have shown that photorefractive keratectomy changes
intraocular pressure (IOP) in myopic eyes by changing the thickness and curvature of the …

Evaluation of intraocular pressure change after laser in situ keratomileusis using the pressure phosphene tonometer

S Naruse, K Mori, M Kojo, O Hieda… - Journal of Cataract & …, 2004 - Elsevier
Purpose: To evaluate the applicability of pressure phosphene tonometry in measuring
intraocular pressure (IOP) after laser in situ keratomileusis (LASIK). Setting: Baptist Eye …

The preoperative intraocular pressure level predicts the amount of underestimated intraocular pressure after LASIK for myopia

E Chihara, H Takahashi, K Okazaki, M Park… - British journal of …, 2005 - bjo.bmj.com
Aims: To evaluate the statistical significance of the parameters that affect underestimation of
intraocular pressure (IOP) after laser in situ keratomileusis (LASIK) for myopia. Methods: In …

Accuracy and predictability of the compensatory function of Orbscan II in intraocular pressure measurements after laser in situ keratomileusis

DH Lee, S Seo, SC Shin, EH Chung… - Journal of Cataract & …, 2002 - Elsevier
Purpose: To evaluate the usefulness of the compensatory function of Orbscan II (Orbtek,
Bausch & Lomb) for measuring postoperative intraoperative pressure (IOP) in laser in situ …