Effect of dependent scattering on the optical properties of Intralipid tissue phantoms

P Di Ninni, F Martelli, G Zaccanti - Biomedical optics express, 2011 - opg.optica.org
The calibration of optical tissue-simulating phantoms remains an open question in spite of
the many techniques proposed for accurate measurements of optical properties. As a …

Intralipid: towards a diffusive reference standard for optical tissue phantoms

P Di Ninni, F Martelli, G Zaccanti - Physics in Medicine & Biology, 2010 - iopscience.iop.org
Measurements of optical properties carried out at visible and NIR wavelengths on many
samples of Intralipid 20% showed a high stability and surprisingly small batch-to-batch …

Dependent scattering in Intralipid® phantoms in the 600-1850 nm range

B Aernouts, R Van Beers, R Watté, J Lammertyn… - Optics express, 2014 - opg.optica.org
The effect of dependent scattering on the bulk scattering properties of intralipid phantoms in
the 600-1850 nm wavelength range has been investigated. A set of 57 liquid optical …

Optical properties measurement of highly diffusive tissue phantoms for biomedical applications

A Rehman, I Ahmad, K Rehman, S Anwar… - Laser …, 2014 - iopscience.iop.org
Extensive research in biomedical optics essentially requires the determination of optical
properties of various biological tissues. Quantitative characterization of biological tissues in …

Intralipid-based phantoms for the development of new optical diagnostic techniques

M Lepore, I Delfino - The Open Biotechnology Journal, 2019 - benthamopen.com
Intralipid is a material widely employed for the preparation of phantoms for optical imaging
and biophotonics applications in medical field. The development of new optical diagnostic …

Dependence of optical scattering from Intralipid in gelatin-gel based tissue-mimicking phantoms on mixing temperature and time

P Lai, X Xu, LV Wang - Journal of biomedical optics, 2014 - spiedigitallibrary.org
Intralipid is widely used as an optical scattering agent in tissue-mimicking phantoms.
Accurate control when using Intralipid is critical to match the optical diffusivity of phantoms to …

Fat emulsions as diffusive reference standards for tissue simulating phantoms?

P Di Ninni, Y Bérubé-Lauzière, L Mercatelli, E Sani… - Applied Optics, 2012 - opg.optica.org
Intralipid 20% was recently suggested as a diffusive reference standard for tissue simulating
phantoms. In this work, we extend previously obtained results to other fat emulsions …

Measurement and analysis of light distribution in Intralipid-10% at 650 nm

T Xu, C Zhang, X Wang, L Zhang, J Tian - Applied optics, 2003 - opg.optica.org
A method for measuring the distributions of light in the biological tissue phantom Intralipid by
use of an optical fiber is presented and measurements of distributions of light in Intralipid …

Surface layering properties of Intralipid phantoms

N Bodenschatz, P Krauter, F Foschum… - Physics in Medicine …, 2015 - iopscience.iop.org
Intralipid has become an extensively studied and widely used reference and calibration
phantom for diffuse optical imaging technologies. In this study we call attention to the …

A solid tissue phantom for photon migration studies

R Cubeddu, A Pifferi, P Taroni… - Physics in Medicine & …, 1997 - iopscience.iop.org
A solid tissue phantom made of agar, Intralipid and black ink is described and characterized.
The preparation procedure is fast and easily implemented with standard laboratory …