[引用][C] Erweiterte Evaluation der Effektivität eines proaktiven forcierten Oszillationstechnik-basierten Auto-CPAP-Algorithmus
SD Herkenrath - 2020 - Dissertation, Köln, Universität zu …
Variability of the treatment pressure under continuous positive airway pressure treatment in obstructive sleep apnea syndrome
W Randerath, C Rocholl, F Feldmeyer… - Pneumologie (Stuttgart …, 2002 - europepmc.org
Background Selfadjusting CPAP therapy is mostly employed if constant CPAP does not
sufficiently suppress respiratory disturbances or is not accepted by the patient. The number …
sufficiently suppress respiratory disturbances or is not accepted by the patient. The number …
Long term performance evaluation of an automatic airway positive pressure device
FC Yen, K Behbehani, JR Burk… - Proceedings of 18th …, 1996 - ieeexplore.ieee.org
Long term studies of automatic continuous positive airway pressure (auto CPAP or APAP)
device is presented. An APAP device is designed to eliminate OSA events automatically. It …
device is presented. An APAP device is designed to eliminate OSA events automatically. It …
Extended evaluation of the efficacy of a proactive forced oscillation technique-based auto-CPAP algorithm
SD Herkenrath, M Treml, N Anduleit, K Richter… - Sleep and …, 2020 - Springer
Purpose Previous studies revealed substantially varying therapy efficacy of automatic
continuous positive airway pressure (APAP) devices in the treatment of obstructive sleep …
continuous positive airway pressure (APAP) devices in the treatment of obstructive sleep …
[引用][C] Predicting Obstructive Sleep Apnea Diagnostic Parameters Under Continuous Positive Airway Pressure Without and with Oscillation
D Al-Mohamadamin, AM Al-Jumaily, S Ashaat - Available at SSRN 4143103
Nonattended home automated continuous positive airway pressure titration: comparison with polysomnography
BT Woodson, A Saurejan… - … –Head and Neck …, 2003 - journals.sagepub.com
OBJECTIVE: Automatic adjusting nasal continuous positive airway pressure titration (APAP)
has been introduced as an alternative method of establishing pressures for patients with …
has been introduced as an alternative method of establishing pressures for patients with …
Early detection of upper airway obstructions by analysis of acoustical respiratory input impedance
S Reisch, H Steltner, J Timmer, C Renotte… - Biological …, 1999 - Springer
Repetitive occurrence of partial or total upper airway obstruction characterizes several
respiratory dysfunctions such as the obstructive sleep apnea syndrome (OSAS). In OSAS …
respiratory dysfunctions such as the obstructive sleep apnea syndrome (OSAS). In OSAS …
Telemonitoring‐guided ambulatory fixed CPAP titration versus ambulatory APAP titration in moderate obstructive sleep apnea: A non‐inferiority randomized controlled …
D Testelmans, D Papadopoulos… - Journal of Sleep …, 2023 - Wiley Online Library
The present study aimed to evaluate whether titration of fixed continuous positive airway
pressure at home using telemonitoring produces patient outcomes equal to auto‐adjusting …
pressure at home using telemonitoring produces patient outcomes equal to auto‐adjusting …
Manual Titration of Positive Airway Pressure in Patients with Obstructive Sleep Apnea
AD Chediak - Sleep Medicine Clinics, 2009 - Elsevier
Positive airway pressure (PAP) devices are used to treat patients who have sleep-related
breathing disorders (SRBD) including obstructive sleep apnea (OSA). After a patient is …
breathing disorders (SRBD) including obstructive sleep apnea (OSA). After a patient is …
Residual sleep-disordered breathing during autotitrating continuous positive airway pressure therapy
AL Denotti, KKH Wong, GC Dungan… - European …, 2012 - Eur Respiratory Soc
Obstructive sleep apnoea (OSA) is often treated with autotitrating continuous positive airway
pressure (autoCPAP) devices. Clinical and bench tests of these devices have suggested …
pressure (autoCPAP) devices. Clinical and bench tests of these devices have suggested …