Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data

V Schulz, I Torres-Espallardo, S Renisch, Z Hu… - European journal of …, 2011 - Springer
Purpose The combination of positron emission tomography (PET) and magnetic resonance
(MR) tomography in a single device is anticipated to be the next step following PET/CT for …

Comparison of segmentation-based attenuation correction methods for PET/MRI: evaluation of bone and liver standardized uptake value with oncologic PET/CT data

JH Kim, JS Lee, IC Song, DS Lee - Journal of Nuclear Medicine, 2012 - Soc Nuclear Med
For attenuation correction (AC) in PET/MRI systems, segmentation-based methods are most
often used. However, the standardized uptake value (SUV) of lesions in the bone and liver …

MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation-and atlas-based methods

M Hofmann, I Bezrukov, F Mantlik… - Journal of Nuclear …, 2011 - Soc Nuclear Med
PET/MRI is an emerging dual-modality imaging technology that requires new approaches to
PET attenuation correction (AC). We assessed 2 algorithms for whole-body MRI-based AC …

Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data

A Martinez-Möller, M Souvatzoglou… - Journal of nuclear …, 2009 - Soc Nuclear Med
Attenuation correction (AC) of whole-body PET data in combined PET/MRI tomographs is
expected to be a technical challenge. In this study, a potential solution based on a …

Whole-body PET/MR imaging: quantitative evaluation of a novel model-based MR attenuation correction method including bone

DH Paulus, HH Quick, C Geppert… - Journal of Nuclear …, 2015 - Soc Nuclear Med
In routine whole-body PET/MR hybrid imaging, attenuation correction (AC) is usually
performed by segmentation methods based on a Dixon MR sequence providing up to 4 …

Whole-body PET/MRI: the effect of bone attenuation during MR-based attenuation correction in oncology imaging

MC Aznar, R Sersar, J Saabye, CN Ladefoged… - European journal of …, 2014 - Elsevier
Abstract Purpose In combined PET/MRI standard PET attenuation correction (AC) is based
on tissue segmentation following dedicated MR sequencing and, typically, bone tissue is not …

The effect of limited MR field of view in MR/PET attenuation correction

G Delso, A Martinez‐Möller, RA Bundschuh… - Medical …, 2010 - Wiley Online Library
Purpose A critical question in the development of combined MR/PET scanners is whether
MR can provide the tissue attenuation data required for PET reconstruction. Unfortunately …

MRI-guided attenuation correction in whole-body PET/MR: assessment of the effect of bone attenuation

A Akbarzadeh, MR Ay, A Ahmadian… - Annals of nuclear …, 2013 - Springer
Abstract Objective Hybrid PET/MRI presents many advantages in comparison with its
counterpart PET/CT in terms of improved soft-tissue contrast, decrease in radiation …

Vision 20/20: magnetic resonance imaging‐guided attenuation correction in PET/MRI: challenges, solutions, and opportunities

A Mehranian, H Arabi, H Zaidi - Medical physics, 2016 - Wiley Online Library
Attenuation correction is an essential component of the long chain of data correction
techniques required to achieve the full potential of quantitative positron emission …

Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI

SH Keller, S Holm, AE Hansen, B Sattler… - … Resonance Materials in …, 2013 - Springer
Purpose Integrated whole-body PET/MRI tomographs have become available. PET/MR
imaging has the potential to supplement, or even replace combined PET/CT imaging in …