Local respiratory motion correction for PET/CT imaging: Application to lung cancer
F Lamare, H Fayad, P Fernandez, D Visvikis - Medical Physics, 2015 - Wiley Online Library
Purpose: Despite multiple methodologies already proposed to correct respiratory motion in
the whole PET imaging field of view (FOV), such approaches have not found wide …
the whole PET imaging field of view (FOV), such approaches have not found wide …
Local respiratory motion correction (LRMC) for PET/CT imaging
F Lamare, M Busch, R Brinks, J Clairet, P Bruyant… - 2007 - Soc Nuclear Med
669 Objectives: The acquisition of respiratory synchronised PET/CT datasets provides
motion compensation but results in poor statistical quality images. However, gated frames …
motion compensation but results in poor statistical quality images. However, gated frames …
Local motion correction for lung tumours in PET/CT—first results
RA Bundschuh, A Martínez-Möller, M Essler… - European journal of …, 2008 - Springer
Purpose Respiratory motion of lung lesions is a limiting factor of quantification of positron
emission tomography (PET) data. As some important applications of PET such as therapy …
emission tomography (PET) data. As some important applications of PET such as therapy …
[HTML][HTML] Impact of respiratory motion correction on lesion visibility and quantification in thoracic PET/MR imaging
M Gratz, V Ruhlmann, L Umutlu, M Fenchel, I Hong… - PLoS …, 2020 - journals.plos.org
The impact of a method for MR-based respiratory motion correction of PET data on lesion
visibility and quantification in patients with oncologic findings in the lung was evaluated …
visibility and quantification in patients with oncologic findings in the lung was evaluated …
Comparison of different methods of incorporating respiratory motion for lung cancer tumor volume delineation on PET images: a simulation study
The interest of PET complementary information for the delineation of the target volume in
radiotherapy of lung cancer is increasing. However, respiratory motion requires the …
radiotherapy of lung cancer is increasing. However, respiratory motion requires the …
Rigid vs. non-rigid motion correction for respiratory gated PET
N Detorie, M Dahlbom - 2007 - Soc Nuclear Med
1717 Objectives: The aim of this study was to investigate the feasibility of a rigid motion
correction method for respiratory gated positron emission tomography (PET). Methods: The …
correction method for respiratory gated positron emission tomography (PET). Methods: The …
Event‐by‐event respiratory motion correction for PET with 3D internal‐1D external motion correlation
Purpose: Respiratory motion during PET/CT imaging can cause substantial image blurring
and underestimation of tracer concentration for both static and dynamic studies. In this study …
and underestimation of tracer concentration for both static and dynamic studies. In this study …
Reconstruction-incorporated respiratory motion correction in clinical simultaneous PET/MR imaging for oncology applications
H Fayad, H Schmidt, C Wuerslin… - Journal of Nuclear …, 2015 - Soc Nuclear Med
Simultaneous PET and MR imaging is a promising new technique allowing the fusion of
functional (PET) and anatomic/functional (MR) information. In the thoracic–abdominal …
functional (PET) and anatomic/functional (MR) information. In the thoracic–abdominal …
Respiratory Motion Correction Strategies in Thoracic PET-CT Imaging.
SA Nehmeh - PET clinics, 2012 - europepmc.org
PET-CT scanners allow robust and synergistic fusion of anatomic and functional information,
which has improved sensitivity, specificity, and enhancement in the value of PET and CT …
which has improved sensitivity, specificity, and enhancement in the value of PET and CT …
Initial evaluation of a practical PET respiratory motion correction method in clinical simultaneous PET/MRI
Respiratory motion during PET acquisitions can cause image artefacts, with sharpness and
tracer quantification adversely affected due to count 'smearing'. Motion correction by …
tracer quantification adversely affected due to count 'smearing'. Motion correction by …