Experimental verification the electron return effect around spherical air cavities for the MR‐Linac using Monte Carlo calculation
Purpose Dose deposition around unplanned air cavities during magnetic resonance‐guided
radiotherapy (MRgRT) is influenced by the electron return effect (ERE). This is clinically …
radiotherapy (MRgRT) is influenced by the electron return effect (ERE). This is clinically …
Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
F Padilla‐Cabal, J Alejandro Fragoso… - Medical …, 2020 - Wiley Online Library
Purpose Magnetic resonance guidance in proton therapy (MRPT) is expected to improve its
current performance. The combination of magnetic fields with clinical proton beam lines …
current performance. The combination of magnetic fields with clinical proton beam lines …
Monte Carlo study of ionization chamber magnetic field correction factors as a function of angle and beam quality
VN Malkov, DWO Rogers - Medical Physics, 2018 - Wiley Online Library
Purpose To use EGSnrc Monte Carlo simulations for magnetic field dosimetry to determine
optimal measurement orientations, calculate beam quality conversion factors for 32 …
optimal measurement orientations, calculate beam quality conversion factors for 32 …
Ion chamber angular dependence in a magnetic field
Purpose There have been several studies investigating dose deposition effects within
radiation detectors in the presence of a magnetic field. However, to date there has only been …
radiation detectors in the presence of a magnetic field. However, to date there has only been …
Experimental verification of a CT‐based Monte Carlo dose‐calculation method in heterogeneous phantoms
L Wang, M Lovelock, CS Chui - Medical physics, 1999 - Wiley Online Library
To further validate the Monte Carlo dose‐calculation method [Med. Phys. 25, 867–878
(1998)] developed at the Memorial Sloan‐Kettering Cancer Center, we have performed …
(1998)] developed at the Memorial Sloan‐Kettering Cancer Center, we have performed …
Characteristics and quality assurance of a dedicated open 0.23 T MRI for radiation therapy simulation
A commercially available open MRI unit is under routine use for radiation therapy simulation.
The effects of a gradient distortion correction (GDC) program used to post process the …
The effects of a gradient distortion correction (GDC) program used to post process the …
Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose increase at tissue–air interfaces in a lateral magnetic field due to returning electrons
AJE Raaijmakers, BW Raaymakers… - Physics in Medicine & …, 2005 - iopscience.iop.org
In the framework of the development of the integration of a MRI-scanner with a linear
accelerator, the influence of a lateral, magnetic field on the dose distribution has to be …
accelerator, the influence of a lateral, magnetic field on the dose distribution has to be …
Fano cavity test for electron Monte Carlo transport algorithms in magnetic fields: comparison between EGSnrc, PENELOPE, MCNP6 and Geant4
A Fano cavity test was performed for four general-purpose Monte Carlo codes, EGSnrc,
PENELOPE, MCNP6 and Geant4 to evaluate the accuracy of their electron transport …
PENELOPE, MCNP6 and Geant4 to evaluate the accuracy of their electron transport …
Experimental verification of dose enhancement effects in a lung phantom from inline magnetic fields
BM Oborn, MA Gargett, TJ Causer, SJ Alnaghy… - Radiotherapy and …, 2017 - Elsevier
Background and purpose To present experimental evidence of lung dose enhancement
effects caused by strong inline magnetic fields. Materials and methods A permanent magnet …
effects caused by strong inline magnetic fields. Materials and methods A permanent magnet …
Consequences of air around an ionization chamber: are existing solid phantoms suitable for reference dosimetry on an MR‐linac?
SL Hackett, B Van Asselen, JWH Wolthaus… - Medical …, 2016 - Wiley Online Library
Purpose: A protocol for reference dosimetry for the MR‐linac is under development. The 1.5
T magnetic field changes the mean path length of electrons in an air‐filled ionization …
T magnetic field changes the mean path length of electrons in an air‐filled ionization …