[HTML][HTML] Impact of bicarbonate interference on routine ion-selective electrode chloride measurements

T Monteyne, M Oyaert, A Van Dalem… - Annals of laboratory …, 2022 - ncbi.nlm.nih.gov
Background Chloride measurement is crucial for calculating the anion gap. Bicarbonate can
interfere with chloride measurements; however, there is no information on the specific types …

Automated analyzer for the determination of potassium and sodium in whole blood

RA Durst - Clinica Chimica Acta, 1977 - Elsevier
An automated analyzer for the measurement of potassium and sodium in whole blood has
been developed and evaluated. The sensors used in this instrument are the sodium glass …

Intermethod variability of sodium and potassium results: patients sera and commercially available control sera

G Cattozzo, A Fabi, C Franzini - 1997 - degruyter.com
Sodium and potassium were measured in sets of 102 to 107 patients sera, and in 31
commercially available control sera. The results from four routine analytical …

Studies on bis (crown ether)-based ion-selective electrodes for the potentiometric determination of sodium and potassium in serum

GJ Moody, BB Saad, JDR Thomas - Analyst, 1989 - pubs.rsc.org
Bis (crown ether)-based ion-selective electrodes for sodium and potassium are described,
based on the bis [(12-crown-4)-2-ylmethyl]-2-dodecyl-2-methyl malonate sensor (I) for …

Activity and interference effects in measurement of ionized calcium with ion-selective electrodes.

JM Grima, MJ Brand - Clinical chemistry, 1977 - academic.oup.com
We assessed the magnitude of the errors in ionized-calcium measurements resulting from
changes in electrolyte composition for three different ion-selective electrodes: the Orion …

[引用][C] Selectivity of enzymatic assays of sodium and potassium

G Steen, B Van Leeuwen, P Langeslag… - Clinical …, 1994 - academic.oup.com
The comments on the one-tailed test are correct. The reason for the higher percentage
changes that they illustrate with the one-sided tests is that the false positives on the opposite …

[引用][C] Cation content of serum as determined by ion chromatography and with ion-selective electrodes.

H Shintani - Clinical chemistry, 1986 - academic.oup.com
Na 139.9±3.8 4.0±0.4 2.7±0.3 Ca levelof 0.1%. cutoff: 15000) and the ultraiiltrate wa tested
both 20-fold diluted and undiluted, respectively, for Na and K. A separate 1-mL sample of the …

Sodium and potassium measurements: direct potentiometry and flame photometry.

NF MacDonald, PZ Williams, JI Burton… - American Journal of …, 1981 - europepmc.org
Data from the 1979 and part of the 1980 College of American Pathologists (CAP) Chemistry
Survey Program have been reviewed in order to compare the direct potentiometric …

[引用][C] Sodium results for urine with the Beckman electrolyte 2 ion-selective electrolyte analyzer are dependent on potassium concentration.

GA Harff - Clinical chemistry, 1982 - academic.oup.com
The message of our paper has been misinterpreted. We asserted that im-munofixation(IF)
should be supported (and not replaced) by immunoelectrophoresis (IEP) for difficult cases …

Glucose interference in direct ion-sensitive electrode sodium measurements

A Al-Musheifri, GRD Jones - Annals of clinical Biochemistry, 2008 - journals.sagepub.com
Circulating sodium concentration is commonly measured by both direct and indirect ion-
sensitive electrode (ISE). We describe an unusual case with a high elevation of serum …