Single-shot grating-based x-ray differential phase contrast imaging with a modified analyzer grating

CX Wei, Z Wu, F Wali, WB Wei, Y Bao, RH Luo… - Chinese …, 2017 - iopscience.iop.org
X-ray grating interferometer has attracted widely attention in the past years due to its
capability in achieving x-ray phase contrast imaging with low brilliance source. However, the …

Correcting Intensity Drift in X-ray Grating-based Phase Contrast Imaging

P Zhang, Q Shao, R Hu, S Wang, G Zan… - Journal of …, 2016 - iopscience.iop.org
X-ray phase-contrast imaging has become an attractive technique because it can deliver
additional information on weakly absorbing materials. Grating-based phase contrast …

Noise analysis of grating-based x-ray differential phase-contrast imaging with angular signal radiography

W Faiz, Y Bao, K Gao, Z Wu, CX Wei, GB Zan… - Chinese …, 2017 - iopscience.iop.org
X-ray phase-contrast imaging is one of the novel techniques, and has potential to enhance
image quality and provide the details of inner structures nondestructively. In this work, we …

Fast x-ray differential phase contrast imaging with one exposure and without movements

J Fu, X Shi, W Guo, P Peng - Scientific Reports, 2019 - nature.com
Grating interferometry X-ray differential phase contrast imaging (GI-XDPCI) has provided
enhanced imaging contrast and attracted more and more interests. Currently the low …

Non-absorption grating approach for x-ray phase contrast imaging

Y Du, X Liu, Y Lei, J Guo, H Niu - Optics express, 2011 - opg.optica.org
we demonstrate a non-absorption grating approach for X-ray phase contrast imaging based-
on grating interferometry. This technique overcomes the limitations imposed by absorption …

A user-friendly LabVIEW software platform for grating based X-ray phase-contrast imaging

S Wang, H Han, K Gao, Z Wang… - Journal of X-Ray …, 2015 - content.iospress.com
X-ray phase-contrast imaging can provide greatly improved contrast over conventional
absorption-based imaging for weakly absorbing samples, such as biological soft tissues and …

Grating based x-ray differential phase contrast imaging without mechanical phase stepping

Y Ge, K Li, J Garrett, GH Chen - Optics Express, 2014 - opg.optica.org
Grating-based x-ray differential phase contrast imaging (DPCI) often uses a phase stepping
procedure to acquire data that enables the extraction of phase information. This method …

Grating interferometer based scanning setup for hard x-ray phase contrast imaging

C Kottler, F Pfeiffer, O Bunk, C Grünzweig… - Review of Scientific …, 2007 - pubs.aip.org
In x-ray radiography, particularly for technical and industrial applications, a scanning setup
is very often favorable when compared to a direct two-dimensional image acquisition. Here …

Development of key devices of grating-based X-ray phase-contrast imaging technology at Shenzhen University

J Guo, X Liu, B Zhou, Y Du, Y Lei, H Niu - AIP Conference Proceedings, 2012 - pubs.aip.org
In this paper, the advance in the key devices of grating-based x-ray phase-contrast imaging
technique, including a new x-ray tube, an x-ray phase grating, and an x-ray image detector …

[引用][C] Detector Correction Method Retaining Source Grating in Grating-based X-ray Phase-contrast Imaging

R HU, D FENG, Z WU, K GAO, Z PAN, G LIU - Atomic Energy Science and …, 2018