Estimation of specific absorbed fractions for selected organs due to photons emitted by activity deposited in the human respiratory tract using ICRP/ICRU male voxel …

HK Patni, DK Akar, MY Nadar, VP Ghare… - Radiation protection …, 2013 - academic.oup.com
The ICRP/ICRU adult male reference voxel phantom incorporated in Monte Carlo code
FLUKA is used for estimating specific absorbed fractions (SAFs) for photons due to the …

Application of the ICRP/ICRU reference computational phantoms to internal dosimetry: calculation of specific absorbed fractions of energy for photons and electrons

L Hadid, A Desbrée, H Schlattl, D Franck… - Physics in Medicine …, 2010 - iopscience.iop.org
The emission of radiation from a contaminated body region is connected with the dose
received by radiosensitive tissue through the specific absorbed fractions (SAFs) of emitted …

Impact on 141Ce, 144Ce, 95Zr, and 90Sr beta emitter dose coefficients of photon and electron SAFs calculated with ICRP/ICRU reference adult voxel computational …

WB Li, M Zankl, H Schlattl, N Petoussi-Henss… - Health …, 2010 - journals.lww.com
The current dose coefficients for internal dose assessment of occupationally exposed
persons and the general public were derived using the methodology of the International …

Selected organ dose conversion coefficients for external photons calculated using ICRP adult voxel phantoms and Monte Carlo code FLUKA

HK Patni, MY Nadar, DK Akar, S Bhati… - Radiation protection …, 2011 - academic.oup.com
The adult reference male and female computational voxel phantoms recommended by ICRP
are adapted into the Monte Carlo transport code FLUKA. The FLUKA code is then utilised for …

Evaluation of specific absorbed fractions from internal photon sources in the ICRP Reference Male Phantom

JC Ocampo, JA Puerta, J Morales - Radiation protection …, 2013 - academic.oup.com
In order to estimate the dose caused by internal radiation, it is necessary to know the specific
absorbed fraction (SAF) values; through this work these values have been calculated using …

Evaluation of specific absorbed fractions from internal photon sources in ORNL analytical adult phantom

HM Hakimabad, LR Motavalli - Radiation protection dosimetry, 2008 - academic.oup.com
To design a diagnostic or therapeutic irradiation programme, there is a need to estimate the
absorbed dose. In this investigation, specific absorbed fractions (SAFs) were calculated …

Assessment of uncertainties in the lung activity measurement of low-energy photon emitters using Monte Carlo simulation of ICRP male thorax voxel phantom

MY Nadar, DK Akar, DD Rao… - Radiation protection …, 2015 - academic.oup.com
Assessment of intake due to long-lived actinides by inhalation pathway is carried out by lung
monitoring of the radiation workers inside totally shielded steel room using sensitive …

The application of voxel phantoms to the internal dosimetry of radionuclides

M Zankl, N Petoussi-Henss, U Fill… - Radiation protection …, 2003 - academic.oup.com
Extensive calculations of specific absorbed fractions (SAFs) for monoenergetic photon
sources were performed using a Monte Carlo photon transport code together with seven …

Voxel anthropomorphic models as a tool for internal dosimetry

N Petoussi-Henss, M Zankl - Radiation protection dosimetry, 1998 - academic.oup.com
Abstract Specific Absorbed Fractions (SAF), which specify the fraction of the energy emitted
by radioactivity in a given organ which is absorbed in the source organ itself and in other …

InterDosi simulations of photon and alpha specific absorbed fractions in zubal voxelized phantom

JEL Bakkali, A Doudouh, TEL Bardouni - Applied Radiation and Isotopes, 2021 - Elsevier
In this work we used the InterDosi code to estimate photon specific absorbed fractions
(SAFs) for some organs of the Zubal adult male voxelized phantom. Chemical compositions …