A study of the bond degradation of rebar due to cathodic protection current

JJ Chang - Cement and Concrete Research, 2002 - Elsevier
Bond degradation of rebar embedded in concrete due to impressed cathodic protection
current was studied and is reported in this paper. Different mix designs of concrete are found …

Evaluation of the bond properties between concrete and reinforcement as a function of the degree of reinforcement corrosion

HS Lee, T Noguchi, F Tomosawa - Cement and Concrete research, 2002 - Elsevier
In order to investigate the effect of reinforcement corrosion on the bond properties between
concrete and reinforcement, the pullout tests were conducted using reinforcements …

Electrochemical study the corrosion behaviour of carbon steel in mortars under compressive and tensile stresses

X Feng, X Lu, Y Zuo, N Zhuang, D Chen - Corrosion Science, 2016 - Elsevier
The influence of compressive and tensile stresses on the corrosion behaviour of the rebar in
mortars was investigated. The corrosion of the rebar intensified with increasing magnitude of …

Degradation of bond between reinforcing steel and concrete due to cathodic protection current

MG Ali, GJ Alsulaimani - Materials Journal, 1993 - concrete.org
Chemical analysis data show a significant electromigration of cations and anions present in
the pore solution of concrete. This results in an accumulation of Na+ and K+ in the vicinity of …

Effect of cathodic protection on steel–concrete bond strength using ion migration measurements

J García, F Almeraya, C Barrios, C Gaona… - Cement and Concrete …, 2012 - Elsevier
Impressed current cathodic protection (ICCP) is a widely used method to protect steel
reinforcements against corrosion. Bond degradation between concrete and steel at …

[HTML][HTML] Impact of corrosion on the bond strength between concrete and rebar: A systematic review

AS Syll, T Kanakubo - Materials, 2022 - mdpi.com
Corrosion of the reinforcement affects more than the cross-sectional area of the rebar. The
volume of steel also increases due to expansive corrosion products, leading to the cracking …

Current distribution in reinforced concrete cathodic protection system with conductive mortar overlay anode

J Xu, W Yao - Construction and Building Materials, 2009 - Elsevier
The current distribution was studied in a designed three-layer reinforced concrete cathodic
protection (CP) system, with carbon fibre reinforced cement (CFRC) as the conductive …

[HTML][HTML] An experimental study of cathodic protection for chloride contaminated reinforced concrete

HM Oleiwi, Y Wang, M Curioni, X Chen, G Yao… - Materials and …, 2018 - Springer
Cathodic protection (CP) is being increasingly used on reinforced concrete structures to
protect steel reinforcing bars from corrosion in aggressive conditions. Due to the complexity …

Corrosion propagation of carbon steel rebar embedded in concrete

FJ Presuel-Moreno, K Hoque - NACE CORROSION, 2019 - onepetro.org
Specimens with binary and ternary concrete mixtures were prepared. The specimens were
reinforced with a# 3 rebar and have 0.75 cm concrete cover. Electromigration was used to …

An experimental study on the bond strength between reinforcement bars and concrete as a function of concrete cover, strength and corrosion level

H Yalciner, O Eren, S Sensoy - Cement and Concrete Research, 2012 - Elsevier
The effect of corrosion on the bond strength between reinforcement bars and concrete was
studied in a series of experiments. An accelerated corrosion method was used to corrode …