Hemorheologic changes in preoperative hemodilution during total hip replacement. Randomized study comparing hydroxyethyl starch 200,000/0.62 (HES) and a …
B Lartigue, J Barre, P Nguyen… - Journal des Maladies …, 1994 - europepmc.org
Hemodilution can be used to save blood transfusion during total hip replacement. We have
carried out a randomized study to compare the hemorheological effects of two plasma …
carried out a randomized study to compare the hemorheological effects of two plasma …
MECHANICAL HEMOLYSIS IN AORTIC VALVULAR DISEASE AND AORTIC BALL‐VALVE PROSTHESIS
E Myhre, K Rasmussen - Acta Medica Scandinavica, 1969 - Wiley Online Library
Using serum haptoglobin concentration as an index, the frequency of hemolysis has been
determined in 110 consecutive, non‐selected patients with aortic valvular lesions admitted …
determined in 110 consecutive, non‐selected patients with aortic valvular lesions admitted …
Mechanical fragility of erythrocytes in normals and in patients with heart valve prostheses
J Dale, E Myhre - Acta Medica Scandinavica, 1971 - Wiley Online Library
Hemolysis following insertion of heart ball valves shows great individual differences.
Besides the mechanical properties of the prosthetic valves, individual variations in the …
Besides the mechanical properties of the prosthetic valves, individual variations in the …
Blood and plasma viscosity and microvascular function in hemodilution
MC Mazzoni, AG Tsai… - European surgical …, 2002 - search.proquest.com
The efficacy of restoring of blood volume by means of colloidal solutions was established on
firm physiological basis when Messmer and co-workers [1] performed a series of pioneering …
firm physiological basis when Messmer and co-workers [1] performed a series of pioneering …
Characteristics of blood rheology in patients during Novacor left ventricular assist system support
TC HUNG, DB BUTTER, RL KORMOS, Z SUN… - ASAIO …, 1989 - journals.lww.com
Blood rheologic properties were studied in 11 patients on Novacor LVAS support (1–126
days) as a bridge to transplantation. Overall, these patients showed slight increases in mean …
days) as a bridge to transplantation. Overall, these patients showed slight increases in mean …
[引用][C] Viscosity studies of blood, plasma, and plasma substitutes
K Reemtsma, O Creech Jr - The Journal of Thoracic and Cardiovascular …, 1962 - Elsevier
Levels.—At hematocrit levels between 10 and 40 per cent, there was only slight increase in
viscosity with increasing hematocrits. However, above 40 per cent, the viscosity increased …
viscosity with increasing hematocrits. However, above 40 per cent, the viscosity increased …
Chronic intravascular hemolysis after aortic valve replacement: Long-term study comparing different types of ball-valve prostheses
E EYSTER, J ROTHCHILD, O MYCHAJLIW - Circulation, 1971 - Am Heart Assoc
To assess the severity of hemolysis and to determine whether severity of hemolysis was
related to type of prosthesis, hematocrit readings (Hct), schistocyte counts (S), reticulocyte …
related to type of prosthesis, hematocrit readings (Hct), schistocyte counts (S), reticulocyte …
Transfusion of fresh whole blood stored (4° C) for short period fails to improve platelet aggregation on extracellular matrix and clinical hemostasis after …
M Golan, M Modan, J Lavee, U Martinowitz… - The Journal of Thoracic …, 1990 - Elsevier
It has recently been shown that the hemostatic effect of 1 unit of fresh whole blood is
equivalent to the effect of 8 to 10 platelet units. This study was designed to evaluate the …
equivalent to the effect of 8 to 10 platelet units. This study was designed to evaluate the …
Intravascular hemolysis in the late course of aortic valve replacement. Relation to valve type, size, and function
J Dale, E Myhre - American heart journal, 1978 - Elsevier
The degree of intravascular hemolysis was evaluated in 315 patients in the late course of
aortic valve replacement. Starr-Edwards aortic ball valves of series 2300 caused …
aortic valve replacement. Starr-Edwards aortic ball valves of series 2300 caused …