Practicable assessment of cochlear size and shape from clinical CT images

AH Gee, Y Zhao, GM Treece, ML Bance - Scientific Reports, 2021 - nature.com
There is considerable interpersonal variation in the size and shape of the human cochlea,
with evident consequences for cochlear implantation. The ability to characterize a specific …

Applications of visualizing cochlear basal turn in cochlear implantation

S Sugarova, V Kuzovkov, F Altamimi… - Laryngoscope …, 2023 - Wiley Online Library
Objective To report a reliable method in obtaining optimal cochlear basal turn and cross‐
section (c/s) of internal auditory canal (IAC) supporting Cochlear implantation (CI) …

[HTML][HTML] Variations in cochlear size of cochlear implant candidates

D Zahara, RD Dewi, A Aboet, FM Putranto… - International archives …, 2019 - SciELO Brasil
Introduction The cochlear anatomy varies in each individual, and that has an impact on
decisions regarding the insertion of electrodes. The measurement of the cochlear size is the …

Surgical anatomy of the basal turn of the human cochlea as pertaining to cochlear implantation

A Singla, D Sahni, AK Gupta, A Aggarwal… - Otology & …, 2015 - journals.lww.com
Background Cochlear implantation is an established mode of treatment for patients with
bilateral, profound sensorineural hearing loss. The intricate knowledge of the anatomy of the …

Diversity in cochlear morphology and its influence on cochlear implant electrode position

KS van der Marel, JJ Briaire, R Wolterbeek… - Ear and …, 2014 - journals.lww.com
Objectives: To define a minimal set of descriptive parameters for cochlear morphology and
study its influence on the cochlear implant electrode position in relation to surgical insertion …

Comparing linear and non-linear models to estimate the appropriate cochlear implant electrode array length—are current methods precise enough?

NM Weiss, T Breitsprecher, M Wozniak… - European Archives of …, 2024 - Springer
Purpose In cochlear implantation with flexible lateral wall electrode arrays, a cochlear
coverage (CC) range between 70% and 80% is considered ideal for optimal speech …

High-resolution computed tomography-based length assessments of the cochlea–an accuracy evaluation

U Kisser, B Ertl-Wagner, JM Hempel, J Müller… - Acta Oto …, 2014 - Taylor & Francis
Conclusion: The length of the cochlea can be determined with good precision using a 3D-
curved multiplanar reconstruction analysis technique and linear reconstruction of the …

Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes

GB Wanna, JH Noble, ML Carlson… - The …, 2014 - Wiley Online Library
Objectives/Hypothesis Three surgical approaches: cochleostomy (C), round window (RW),
and extended round window (ERW); and two electrodes types: lateral wall (LW) and …

Radiological measurement of cochlear dimensions in cochlear hypoplasia and its effect on cochlear implant selection

G Pamuk, AE Pamuk, A Akgöz, MD Bajin… - The Journal of …, 2021 - cambridge.org
ObjectiveTo determine the effect of cochlear dimensions on cochlear implant selection in
cochlear hypoplasia patients. MethodsTemporal bone computed tomography images of 36 …

[PDF][PDF] In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays

DR Ketten, MW Skinner, GE Wang… - ANNALS OF …, 1998 - academia.edu
Three-dimensional cochlear canal lengths, electrode array intracochlear insertion depths,
and characteristic frequency ranges were estimated for 20 Nucleus implant recipients on the …