[PDF][PDF] Measurement of serum sodium and potassium with direct ion-selective electrode systems

K Dewitte, D Stöckl, LM Thienpont - Clin Chim Acta, 1999 - academia.edu
In a recent article in this journal, Rodriguez-Garcia et al.[1] reported about transferability of
results for serum sodium and potassium between different analysers. Four of the seven …

[引用][C] Standardization of sodium/potassium revisited

MF Burritt - Clinical chemistry, 1992 - academic.oup.com
With the pending new CLIA regulations, the issue of standardization has become more
important. AACC's efforts in the areas of standardization and development of standard …

Recommendations for measurement of and conventions for reporting sodium and potassium by ion-selective electrodes in undiluted serum, plasma or whole blood

RW Burnett, AK Covington, N Fogh-Andersen… - 2000 - degruyter.com
Ion-selective electrodes (ISEs) respond to ion-activity and therefore do not sense substance
concentration directly. However, it is recognized that sodium and potassium in plasma will …

Proposed Recommendations on Ion-Selective Electrode Determinations of the Substance Concentration of Sodium, Potassium and Ionized Calcium in Serum Plasma …

AHJ Maas - Clinical Chemistry: An Overview, 1987 - Springer
Ion-selective electrodes (ISEs) make possible the measurement of a wide range of analytes,
which cover such diverse substances as ions, dissolved gases, enzymes etc. in serum …

Automated analyzer for the determination of potassium and sodium in whole blood

RA Durst - Clinica Chimica Acta, 1977 - Elsevier
An automated analyzer for the measurement of potassium and sodium in whole blood has
been developed and evaluated. The sensors used in this instrument are the sodium glass …

Reference methods for the determination of sodium, potassium, pH and blood gases with ion-selective electrodes

WR Külpmann - 1991 - degruyter.com
The determination of sodium and potassium in serum will be performed in the near future
mainly by ion-selective electrodes. When the samples are highly diluted before …

International consensus on the standardization of sodium and potassium measurements by ion-selective electrodes in undiluted samples

WR Küpmann, T Höbbel - Scandinavian journal of clinical and …, 1996 - Taylor & Francis
The International Federation of Clinical Chemistry (FCC) and the National Committee for
Clinical Laboratory Standards (NCCLS) are about to recommend to adjust sodium and …

Determination of sodium and potassium with ion-selective electrodes.

N Fogh-Andersen, PD Wimberley, J Thode… - Clinical …, 1984 - academic.oup.com
We compared different sample-handling techniques for measurement of Na+ and K+ with
ion-selective electrodes (ISE). Imprecision was less for venous blood (with a minimum of …

International Federation of Clinical Chemistry (IFCC). Recommendation on mean molar activity coefficients and single ion activity coefficients of solutions for …

RW Burnett, AK Covington… - European Journal of …, 1997 - europepmc.org
In principle, flame photometry measures substance concentration, and ion-selective
electrodes (ISEs) measure ion activity. However, the situation regarding the comparison of …

Frozen human serum reference material for standardization of sodium and potassium measurements in serum or plasma by ion-selective electrode analyzers

PC Gunaratna, WF Koch, RC Paule… - Clinical …, 1992 - academic.oup.com
Three interlaboratory round-robin studies (RR1, RR2, and RR3) were conducted to identify a
serum-based reference material that would aid in the standardization of direct ion-selective …