Effect of respiratory phases on MR lung signal intensity and lung conspicuity using segmented multiple inversion recovery turbo spin echo (MIR‐TSE)

VM Mai, Q Chen, W Li, H Hatabu… - … in Medicine: An …, 2000 - Wiley Online Library
The purpose of this study was to determine the effect of respiratory phase on signal intensity
of the lung. Lung images were obtained from eleven healthy human volunteers using a …

1H magnetic resonance imaging of human lung using inversion recovery turbo spin echo

VM Mai, J Knight‐Scott, RR Edelman… - Journal of Magnetic …, 2000 - Wiley Online Library
Abstract Evaluation of lung pathologies using magnetic resonance imaging remains limited,
primarily due to the lung's low proton density and high density of magnetic field susceptibility …

Multiple inversion recovery MR subtraction imaging of human ventilation from inhalation of room air and pure oxygen

VM Mai, Q Chen, AA Bankier… - Magnetic resonance in …, 2000 - Wiley Online Library
The feasibility of MR subtraction imaging of lung ventilation using air against oxygen using a
multiple inversion recovery half‐Fourier single‐shot turbo spin echo (MIR‐HASTE) …

MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence

H Hatabu, J Gaa, E Tadamura, KJ Edinburgh… - European journal of …, 1999 - Elsevier
Objective: To evaluate the utility of a half-Fourier single-shot turbo spin-echo sequence
(HASTE) at depicting lung parenchyma and lung pathology. Methods and patients: A HASTE …

Improved visualization of the human lung in 1H MRI using multiple inversion recovery for simultaneous suppression of signal contributions from fat and muscle

VM Mai, J Knight‐Scott, SS Berr - Magnetic Resonance in …, 1999 - Wiley Online Library
Abstract 1H magnetic resonance imaging of the lung is hampered by the low contrast
between lung parenchyma, and muscle and fat in the thorax. We show that it is possible to …

Magnetization transfer short inversion time inversion recovery enhanced1H MRI of the human lung

PM Jakob, T Wang, G Schultz, H Hebestreit… - … Resonance Materials in …, 2002 - Springer
The unique characteristics of the human lung arising from low proton density and multiple air-
tissue interfaces of the alveoli cause difficulty in 1 H lung magnetic resonance imaging. In …

Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory …

J Biederer, M Reuter, M Both, C Muhle, J Grimm… - European …, 2002 - Springer
The aim of this study was to evaluate feasibility and limitations of two MR sequences for
imaging of the lung using a semi-quantitative rating scale. Ten healthy volunteers were …

Temporal dynamics of blood flow effects in half‐Fourier fast spin echo 1H magnetic resonance imaging of the human lungs

J Knight‐Scott, SD Keilholz‐George… - Journal of Magnetic …, 2001 - Wiley Online Library
A cardiac‐triggered half‐Fourier single‐shot turbo spin echo (HASTE) technique is currently
the method of choice for MR imaging of the lung parenchyma without the use of exogenous …

Optimization and evaluation of the signal intensity change in multisection oxygen‐enhanced MR lung imaging

R Löffler, CJ Müller, M Peller… - Magnetic resonance …, 2000 - Wiley Online Library
The behavior of the signal intensity in MRI of human lungs was investigated during
inhalation of pure oxygen. Nine volunteers were examined, five using a breath‐hold and …

Influence of inversion pulse type in assessing lung‐oxygen‐enhancement by centrically‐reordered non‐slice‐selective inversion‐recovery half‐Fourier single‐shot …

M Puderbach, Y Ohno, H Kawamitsu… - Journal of Magnetic …, 2007 - Wiley Online Library
Purpose To demonstrate the influence of inversion pulse type and inversion time for
assessment of oxygen‐enhancement on centrically‐reordered non‐slice‐selective inversion …