Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT

M Peszynska-Piorun, J Malicki… - Radiology and oncology, 2012 - sciendo.com
Background. Treatment planning for head and neck (H&N) cancer is complex due to the
number of organs at risk (OAR) located near the planning treatment volume (PTV). Distant …

Comparing 3DCRT and inversely optimized IMRT planning for head and neck cancer: equivalence between step-and-shoot and sliding window techniques

B Longobardi, E De Martin, C Fiorino, I Dell'oca… - Radiotherapy and …, 2005 - Elsevier
BACKGROUND AND PURPOSE: To investigate the feasibility and the advantages of using
Intensity-Modulated Radiotherapy (IMRT) for the treatment of head-and-neck cancer …

Beam path toxicities to non-target structures during intensity-modulated radiation therapy for head and neck cancer

DI Rosenthal, MS Chambers, CD Fuller… - International Journal of …, 2008 - Elsevier
BACKGROUND: Intensity-modulated radiation therapy (IMRT) beams traverse nontarget
normal structures not irradiated during three-dimensional conformal RT (3D-CRT) for head …

3D conformal, IMRT and VMAT for the treatment of head and neck cancer: a brief literature review

KT Afrin, S Ahmad - Journal of Radiotherapy in Practice, 2022 - cambridge.org
Aim: The objective of this study has been to identify monitor unit (MU) and treatment time
variations, volume coverage dissimilarity among 3D conformal radiation therapy (3D-CRT) …

Target coverage in head and neck cancer treated with intensity-modulated radiotherapy: a comparison between conventional and conformal techniques

M Palazzi, E Orlandi, E Pignoli, M Lualdi… - Tumori …, 2006 - journals.sagepub.com
Aims and background We designed a comparative planning study aimed at quantifying the
advantages of intensity-modu-lated radiotherapy (IMRT) over the conventional 3-field …

Comparison three-dimensional conformal radiotherapy versus intensity modulated radiation therapy in local control of head and neck cancer

G Ghosh, G Gupta, A Malviya… - Journal of cancer research …, 2018 - journals.lww.com
Background: About 74% of head and neck cancer (HNC) patients need to undergo either
definitive or postoperative radiation therapy because of aggressive nature of disease. The …

Impact of geometric uncertainties on dose distribution during intensity modulated radiotherapy of head-and-neck cancer: the need for a planning target volume and a …

O Ballivy, W Parker, T Vuong, G Shenouda… - Current …, 2006 - mdpi.com
We assessed the effect of geometric uncertainties on target coverage and on dose to the
organs at risk (OARS) during intensity-modulated radiotherapy (IMRT) for head-and-neck …

Adequate margins for random setup uncertainties in head-and-neck IMRT

E Astreinidou, A Bel, CPJ Raaijmakers… - International Journal of …, 2005 - Elsevier
PURPOSE: To investigate the effect of random setup uncertainties on the highly conformal
dose distributions produced by intensity-modulated radiotherapy (IMRT) for clinical head …

Radiobiological evaluation of forward and inverse IMRT using different fractionations for head and neck tumours

BC Ferreira, M do Carmo Lopes, J Mateus, M Capela… - Radiation …, 2010 - Springer
Purpose To quantify the radiobiological advantages obtained by an Improved Forward
Planning technique (IFP) and two IMRT techniques using different fractionation schemes for …

Dose conformation in IMRT for head and neck tumors: which solution to apply?

W De Neve, W Duthoy, F Claus, W De Gersem… - Cancer …, 2002 - Elsevier
At Ghent University Hospital, IMRT for head and neck cancer is routinely performed. The
desired dose distribution is defined upfront as a range of acceptable doses assigned to each …