[HTML][HTML] 3D printed biomodels for flow visualization in stenotic vessels: An experimental and numerical study

V Carvalho, N Rodrigues, R Ribeiro, PF Costa… - Micromachines, 2020 - mdpi.com
Atherosclerosis is one of the most serious and common forms of cardiovascular disease and
a major cause of death and disability worldwide. It is a multifactorial and complex disease …

Design, simulation, and fabrication of a three-dimensional printed pump mimicking the left ventricle motion

E Vignali, Z Manigrasso, E Gasparotti… - … journal of artificial …, 2019 - journals.sagepub.com
The development of accurate replicas of the circulatory and cardiac system is fundamental
for a deeper understanding of cardiovascular diseases and the testing of new devices …

Integrating in-vivo Data in CFD Simulations and in in-vitro Experiments of the Hemodynamic in Healthy and Pathologic Thoracic Aorta

A Mariotti, E Gasparotti, E Vignali, P Marchese… - … Work-Conference on …, 2022 - Springer
A comparison between the results obtained integrating in-vivo measurements in numerical
simulations and in-vitro experiments is presented. Three aorta geometries are considered: a …

Simulation and development of a mock circulation loop with variable compliance

SD Gregory - 2009 - eprints.qut.edu.au
Heart disease is attributed as the highest cause of death in the world. Although this could be
alleviated by heart transplantation, there is a chronic shortage of donor hearts and so …

A mock circulatory system incorporating a compliant 3D‐printed anatomical model to investigate pulmonary hemodynamics

PGM Knoops, G Biglino, AD Hughes, KH Parker… - Artificial …, 2017 - Wiley Online Library
A realistic mock circulatory system (MCS) could be a valuable in vitro testbed to study
human circulatory hemodynamics. The objective of this study was to design a MCS …

[HTML][HTML] A versatile hybrid mock circulation for hydraulic investigations of active and passive cardiovascular implants

A Petrou, M Granegger, M Meboldt, MS Daners - Asaio Journal, 2019 - journals.lww.com
During the development process of active or passive cardiovascular implants, such as
ventricular assist devices or vascular grafts, extensive in-vitro testing is required. The aim of …

[HTML][HTML] Heart blood flow simulation: a perspective review

SN Doost, D Ghista, B Su, L Zhong… - Biomedical engineering …, 2016 - Springer
Cardiovascular disease (CVD), the leading cause of death today, incorporates a wide range
of cardiovascular system malfunctions that affect heart functionality. It is believed that the …

[HTML][HTML] Artificial circulatory model for analysis of human and artificial vessels

A Polanczyk, M Klinger, J Nanobachvili, I Huk… - Applied sciences, 2018 - mdpi.com
Background: Ex vivo computer controlled circulatory reactors are advantageous for the
investigation of circulatory systems. So far, most of the models have dealt with laminar or …

Patient specific hemodynamics: combined 4D flow-sensitive MRI and CFD

AF Stalder, Z Liu, J Hennig, JG Korvink, KC Li… - … for Medicine: Soft …, 2011 - Springer
Both 4D flow-sensitive MRI and computational fluid dynamics (CFD) have successfully been
applied to analyze complex 3D flow patterns in the cardiovascular system. However, both …

In vitro biomodels in stenotic arteries to perform blood analogues flow visualizations and measurements: A review

VM Carvalho, I Maia, AVA Souza, JE Ribeiro, P Costa… - 2020 - bibliotecadigital.ipb.pt
Cardiovascular diseases are one of the leading causes of death globally and the most
common pathological process is atherosclerosis. Over the years, these cardiovascular …