Aortic stenosis caused by the felt strip used in repair for acute aortic dissection

K Matsuura, H Ogino, K Minatoya… - … and Thoracic Surgery, 2004 - academic.oup.com
Objective: We report a rare complication—stenosis of the proximal anastomotic site caused
by an inside felt strip—in surgery for acute type A aortic dissection. Methods: Eight weeks …

Postoperative early hemolytic anemia due to inverted teflon felt strip after emergency repair for type A dissection

M Hata, I Yoshitake, S Wakui… - The Thoracic and …, 2012 - thieme-connect.com
A 39-year-old man underwent emergency surgery for type A acute aortic dissection
complicated by paraplegia. However, hemolytic anemia increased significantly due to …

Hemolytic anemia caused by aortic flap and inversion of felt strip after ascending aorta replacement

M Sakaguchi, T Takano - Journal of Cardiothoracic Surgery, 2016 - Springer
Backgrounds Hemolysis related to a kinked prosthetic graft or inner felt strip is a very rare
complication after aortic surgery. We describe herein a case of hemolytic anemia that …

Hemolytic anemia after operation for aortic dissection using teflon felt strips

Y Nakamura, H Ogino, H Matsuda, K Minatoya… - The Annals of thoracic …, 2008 - Elsevier
We report three cases of hemolytic anemia caused by anastomotic stenosis after surgical
treatment for aortic dissection in which internal and external Teflon (DuPont, Wilmington …

Hemolytic anemia caused by kinked graft 6 months after aortic dissection repair

K Tamura, W Tatsuishi, Y Konishi, N Konno… - Journal of …, 2022 - Springer
Background Clinically insignificant hemolytic anemia is occasionally a complication of
prosthetic valve replacement. However, hemolysis related to kinked grafts is a very rare …

Acute limb ischemia due to embolization of biological glue after repair of type A aortic dissection

E Bernabeu, M Castellá, C Barriuso… - … and thoracic surgery, 2005 - academic.oup.com
Objective: We present two cases of type A aortic dissection repaired with the help of
biological glue, that were followed by acute limb ischemia due to embolism of glue. Methods …

Devastating late complication for repair of type A acute aortic dissection with usage of gelatin-resorcinol-formalin glue

H Izutani, T Shibukawa, J Kawamoto… - Interactive …, 2007 - academic.oup.com
Objectives: We review cases of pseudoaneurysm formation of the graft anastomosis sites
following repair of type A acute aortic dissection by our original leak-proof technique for …

Embolisation, inflammatory reaction and persistent patent false lumen: is biological glue really effective in repair of type A aortic dissection?

P Mastroroberto, M Chello, F Onorati… - European Journal of …, 2005 - academic.oup.com
We read with great interest the case report presented by Hoschtitzky and co-workers on a
patient with acute coronary syndrome following repair of aortic dissection [1] and we would …

A double patch sandwich technique for surgical repair of acute aortic dissection type A

TM Fleck, H Tschernich, M Grabenwoger… - The Annals of thoracic …, 2003 - Elsevier
BACKGROUND: This study compares two groups of patients with acute aortic dissection
type A in whom two different techniques of anastomotic reinforcement were used, and …

Fibrin sealant patch for repair of acute type a aortic dissection

M Lisy, M Kahlil, UA Stock… - Journal of Cardiac …, 2013 - Wiley Online Library
Introduction The use of glues to repair disrupted tissue during acute type‐A aortic dissection
(TAD) surgery may be discontinuous, and cause embolization and cell necrosis. We report a …