Minimally invasive closed circuit versus standard extracorporeal circulation for aortic valve replacement

A Castiglioni, A Verzini, F Pappalardo… - The Annals of thoracic …, 2007 - Elsevier
BACKGROUND: The purpose of this study was to evaluate the safety and clinical results of
aortic valve replacement performed with minimally invasive closed circuit extracorporeal …

Comparison of minimally invasive closed circuit versus standard extracorporeal circulation for aortic valve replacement: a randomized study

A Castiglioni, A Verzini, N Colangelo… - … and thoracic surgery, 2009 - academic.oup.com
To evaluate the clinical results of aortic valve replacement performed with a miniaturized
closed circuit extracorporeal circulation (MECC) system and to compare it to standard …

Aortic valve replacement with minimal extracorporeal circulation versus standard cardiopulmonary bypass

A Colli, C Fernandez, L Delgado… - Interactive …, 2009 - academic.oup.com
The purpose of this study was to evaluate the safety and the clinical outcomes of aortic valve
replacement (AVR) performed with minimally invasive extracorporeal circulation (miniECC) …

Minimally invasive versus standard extracorporeal circulation system in minimally invasive aortic valve surgery: a propensity score-matched study

P Berretta, M Cefarelli, L Montecchiani… - European Journal of …, 2020 - academic.oup.com
OBJECTIVES The impact of minimally invasive extracorporeal circulation (MiECC) systems
on the clinical outcomes of patients undergoing minimally invasive aortic valve replacement …

Minimal access aortic valve replacement using a minimal extracorporeal circulatory system

A Yilmaz, A Rehman, U Sonker… - The Annals of thoracic …, 2009 - Elsevier
BACKGROUND: Minimal access aortic valve replacement (mAVR) has been demonstrated
to be beneficial over standard median sternotomy. Similarly, minimal extracorporeal …

[HTML][HTML] Aortic valve replacement with the minimal extracorporeal circulation (Jostra MECC System) versus standard cardiopulmonary bypass: a randomized …

JP Remadi, Z Rakotoarivello, P Marticho… - The Journal of thoracic …, 2004 - Elsevier
BACKGROUND: We prospectively evaluated a newly introduced minimal extracorporeal
circulation system (Jostra MECC System; Jostra AG, Hirrlingen, Germany) for aortic valve …

Minimally-invasive versus conventional aortic valve replacement–perioperative course and mid-term results

S Christiansen, J Stypmann, TDT Tjan… - European journal of …, 1999 - academic.oup.com
Objective: We performed a case-control-study to compare perioperative and mid-term results
of minimally invasive with conventional aortic valve replacement. Methods: Between 8/96 …

A comparison between minimized extracorporeal circuits and conventional extracorporeal circuits in patients undergoing aortic valve surgery: is 'minimally invasive …

P Starinieri, PE Declercq, B Robic, A Yilmaz… - …, 2017 - journals.sagepub.com
Introduction: Even though results have been encouraging, an unequivocal conclusion on the
beneficial effect of minimally invasive extracorporeal circulation (MiECC) in patients …

Combined coronary artery bypass grafting and aortic valve replacement with minimal extracorporeal closed circuit circulation versus standard cardiopulmonary …

A Yilmaz, J Sjatskig, WJ van Boven… - … and thoracic surgery, 2010 - academic.oup.com
Isolated aortic valve replacement (AVR) or coronary artery bypass grafting (CABG) using
minimized extracorporeal circulation (MECC) has been shown to have less deleterious …

Minimally invasive extracorporeal bypass in minimally invasive heart valve operations: a prospective randomized trial

H Baumbach, CJ Rustenbach, S Ahad, R Nagib… - The Annals of thoracic …, 2016 - Elsevier
Background Minimally invasive extracorporeal circulation (MECC) is predominantly used in
coronary operations. Data supporting the benefits of MECC in minimally invasive valve …