The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system

SA Al-Ghafli, KX Michalakis, H Hirayama… - Journal of Prosthetic …, 2009 - thejpd.org
Purpose. The purpose of this in vitro study was to investigate the effect of cyclic
dislodgement on the retention of an overdenture attachment system when 2 implants were …

In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures.

P Eren Türk, O Geckili, Y Türk… - … Journal of Oral & …, 2014 - search.ebscohost.com
Purpose: To compare the retentive properties of ball and locator attachments during 5,000
insertion-separation cycles, corresponding to approximately 4.5 years of clinical use …

Effects of interimplant distance and cyclic dislodgement on retention of LOCATOR and ball attachments: An in vitro study

R Salehi, SS Shayegh, WM Johnston… - The Journal of Prosthetic …, 2019 - Elsevier
Statement of problem Evaluation of the long-term retentive behavior of overdenture
attachments is necessary for successful treatment. Interimplant distance (IID) could affect the …

Influence of implant angulation and cyclic dislodging on the retentive force of two different overdenture attachments – an in vitro study

M Srinivasan, M Schimmel, I Badoud… - Clinical oral implants …, 2016 - Wiley Online Library
Objective This in vitro study evaluated the influence of implant angulations on the retentive
behavior of two overdenture attachments during cyclic dislodging. Methods Models …

An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures

T Shastry, NM Anupama, S Shetty… - The Journal of Indian …, 2016 - journals.lww.com
Aim: The aim of this in vitro study was to compare the change in the retentive force and
removal torque of three attachment systems during simulation of insertion-removal cycles …

Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems

M Kobayashi, M Srinivasan, P Ammann… - Clinical oral implants …, 2014 - Wiley Online Library
Background Mandibular two‐implant‐retained overdentures were suggested as first choice
of treatment for edentulous mandibles. However, wear of the attachments may reduce their …

In vitro retention force changes during cyclic dislodging of three novel attachment systems for implant overdentures with different implant angulations

S Maniewicz, I Badoud, FR Herrmann… - Clinical oral implants …, 2020 - Wiley Online Library
Objectives This in vitro study aimed to compare changes in retentive force due to cyclic
dislodging of three novel un‐splinted attachments. Materials and Methods Experimental …

Retention of implant‐supported overdentures at different implant angulations: Comparing Locator and ball attachments

N Sultana, DW Bartlett… - Clinical oral implants …, 2017 - Wiley Online Library
Objectives To assess the effect of implant angulation on the retention of two different
attachment systems for implant‐supported overdentures after a simulated fatigue period of …

[HTML][HTML] In vitro retention capacity of two overdenture attachment systems: Locator® and Equator®

N Mínguez-Tomás… - Journal of clinical and …, 2018 - ncbi.nlm.nih.gov
Background It is necessary to know the in vitro behavior of different attachment systems to
be used clinically. The evolution of retention capacity over 10 years (14,600 insertion/de …

Effect of implant angulation upon retention of overdenture attachments

MP Gulizio, JR Agar, JR Kelly… - … : Implant, Esthetic and …, 2005 - Wiley Online Library
Introduction: Overdentures supported and retained by endosteal implants depend upon
mechanical components to provide retention. Ball attachments are frequently described …