Fully self‐gated free‐running 3D Cartesian cardiac CINE with isotropic whole‐heart coverage in less than 2 min
Purpose To develop a novel fast water‐selective free‐breathing 3D Cartesian cardiac CINE
scan with full self‐navigation and isotropic whole‐heart (WH) coverage. Methods A free …
scan with full self‐navigation and isotropic whole‐heart (WH) coverage. Methods A free …
Pulmonary ventilation maps generated with free-breathing proton MRI and a deep convolutional neural network
Background Hyperpolarized noble gas MRI helps measure lung ventilation, but clinical
translation remains limited. Free-breathing proton MRI may help quantify lung function using …
translation remains limited. Free-breathing proton MRI may help quantify lung function using …
Accelerate gas diffusion-weighted MRI for lung morphometry with deep learning
C Duan, H Deng, S Xiao, J Xie, H Li, X Zhao, D Han… - European …, 2022 - Springer
Objectives Multiple b-value gas diffusion-weighted MRI (DW-MRI) enables non-invasive and
quantitative assessment of lung morphometry, but its long acquisition time is not well …
quantitative assessment of lung morphometry, but its long acquisition time is not well …
Improved respiratory efficiency of 3D late gadolinium enhancement imaging using the continuously adaptive windowing strategy (CLAWS)
J Keegan, P Jhooti, SV Babu‐Narayan… - Magnetic resonance …, 2014 - Wiley Online Library
Purpose Acquisition durations of navigator‐gated high‐resolution three‐dimensional late
gadolinium enhancement studies may typically be up to 10 min, depending on the …
gadolinium enhancement studies may typically be up to 10 min, depending on the …
Oxygen enhanced lung MRI by simultaneous measurement of T1 and T2* during free breathing using ultrashort TE
SMF Triphan, FA Breuer, D Gensler… - Journal of Magnetic …, 2015 - Wiley Online Library
Purpose To provide a robust method for the simultaneous quantification of T1 and T2* in the
human lung during free breathing. Breathing pure oxygen accelerates T1 and T2* relaxation …
human lung during free breathing. Breathing pure oxygen accelerates T1 and T2* relaxation …
3D whole‐heart isotropic‐resolution motion‐compensated joint T1/T2 mapping and water/fat imaging
Purpose To develop a free‐breathing isotropic‐resolution whole‐heart joint T1 and T2
mapping sequence with Dixon‐encoding that provides coregistered 3D T1 and T2 maps and …
mapping sequence with Dixon‐encoding that provides coregistered 3D T1 and T2 maps and …
Time efficient 3D radial UTE sampling with fully automatic delay compensation on a clinical 3T MR scanner
This work's aim was to minimize the acquisition time of a radial 3D ultra-short echo-time
(UTE) sequence and to provide fully automated, gradient delay compensated, and therefore …
(UTE) sequence and to provide fully automated, gradient delay compensated, and therefore …
Magnetic resonance imaging of the lung with a volumetric interpolated 3D-gradient echo sequence
J Biederer, J Graessner, M Heller - RöFo-Fortschritte auf dem …, 2001 - thieme-connect.com
Objective: To evaluate the feasibility of a magnetic resonance imaging protocol for the lung
using a volumetric interpolated 3D-gradient echo sequence (3D-GRE). Subjects and …
using a volumetric interpolated 3D-gradient echo sequence (3D-GRE). Subjects and …