Corneal pachymetry in normal and keratoconic eyes: Orbscan II versus ultrasound

D Gherghel, SL Hosking, S Mantry, S Banerjee… - Journal of Cataract & …, 2004 - Elsevier
Purpose: To compare corneal thickness measurements using Orbscan II (OII) and ultrasonic
(US) pachymetry in normal and in keratoconic eyes. Setting: Eye Department, Heartlands …

[HTML][HTML] Central and peripheral corneal thickness measurement in normal and keratoconic eyes using three corneal pachymeters

S Feizi, MR Jafarinasab, F Karimian… - Journal of ophthalmic …, 2014 - ncbi.nlm.nih.gov
Purpose: To assess the agreement among ultrasonic pachymetry, the Galilei dual
Scheimpflug analyzer, and Orbscan II for central and peripheral (Galilei vs. Orbscan) corneal …

Comparison of central corneal thickness measurements by ultrasound pachymetry, konan noncontact optical pachymetry, and orbscan pachymetry

A Christensen, J Narváez, G Zimmerman - Cornea, 2008 - journals.lww.com
Purpose: To assess the repeatability of two optical techniques for measurement of central
corneal thickness and to compare the validity of these techniques with standard ultrasound …

Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry

JM González-Méijome, A Cerviño… - Journal of Cataract & …, 2003 - Elsevier
PURPOSE: To compare thickness measurements of the central 6.0 mm of the cornea
obtained with the Orbscan® II topography system and topographical ultrasound pachymetry …

[HTML][HTML] Measurement of central corneal thickness using ultrasound pachymetry and Orbscan II in normal eyes

MM Sadoughi, B Einollahi, N Einollahi… - Journal of ophthalmic …, 2015 - ncbi.nlm.nih.gov
Purpose: To compare ultrasound pachymetry and Orbscan II for measurement of central
corneal thickness (CCT) in normal eyes. Methods: The current study was performed at …

Comparison of central corneal thickness measurements with a new optical device and a standard ultrasonic pachymeter

G Nemeth, A Tsorbatzoglou, K Kertesz, A Vajas… - Journal of Cataract & …, 2006 - Elsevier
PURPOSE: To compare central corneal thickness (CCT) values obtained with ultrasonic
pachymetry and a new optical method using partial coherence interferometry (PCI) …

Central corneal thickness measured with three optical devices and ultrasound pachometry

J González-Pérez, JM González-Méijome… - Eye & contact …, 2011 - journals.lww.com
Purpose: To evaluate the reliability of three noninvasive pachometry methods against the
ultrasound pachometer considered the gold standard. Methods: Central corneal thickness …

Comparison and reproducibility of corneal thickness and curvature readings obtained by the Galilei and the Orbscan II analysis systems

N Menassa, C Kaufmann, M Goggin… - Journal of Cataract & …, 2008 - journals.lww.com
PURPOSE: To compare central corneal thickness (CCT) and keratometry readings using the
Galilei dual Scheimpflug analyzer, the Orbscan II anterior segment analysis system, and the …

Comparison of central corneal thickness measurements with standard ultrasonic pachymetry and optical devices

M Doğan, E Ertan - Clinical and Experimental Optometry, 2019 - Taylor & Francis
Background To compare the repeatability and agreements of central corneal thickness
measurements of healthy individuals obtained by Scheimpflug‐Placido topographer (Sirius) …

Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness

S Miglior, E Albe, M Guareschi, G Mandelli… - British Journal of …, 2004 - bjo.bmj.com
Purpose: To assess reproducibility of central corneal thickness (CCT) measurement by
means of ultrasonic pachymetry. Methods: Fifty one volunteers underwent three sessions of …