Patency of saphenous vein grafts using the PAS-Port system during coronary artery bypass surgery

H Kubota, H Endo, H Ishii, H Tsuchiya… - The Annals of Thoracic …, 2017 - Elsevier
Background Several proximal anastomosis devices have been developed to shorten the
time required for a proximal anastomosis and to avoid aortic cross-/side-clamping during …

[HTML][HTML] Evaluation of the PAS-Port Proximal Anastomosis System in coronary artery bypass surgery (the EPIC trial)

JD Puskas, ME Halkos, H Balkhy, M Caskey… - The Journal of thoracic …, 2009 - Elsevier
OBJECTIVE: During coronary surgery, proximal vein graft anastomoses have been
performed by using an aortic partial occlusion clamp to allow for a hand-sewn anastomosis …

Sutureless proximal anastomosis using the PAS-Port system: six-month patency and five-year follow-up in “all-comers”

S Demertzis, R Trunfio, F Faletra, R Wyttenbach… - The Annals of thoracic …, 2010 - Elsevier
BACKGROUND: The PAS-Port system (Cardica, Inc, Redwood City, CA) was used routinely
for patients undergoing coronary surgery with at least one venous graft. Graft patency and …

Six-month angiographic follow-up of the PAS-Port II clinical trial

JF Gummert, S Demertzis, K Matschke… - The Annals of thoracic …, 2006 - Elsevier
BACKGROUND: The PAS-Port device (Cardica, Redwood City, CA) allows the rapid
deployment of a clampless proximal anastomosis between a vein graft and the aorta …

[PDF][PDF] Midterm patency rate after saphenous vein grafting with a PAS-Port device

M Kai, M Hanyu, Y Soga, T Nomoto, J Nakano… - The Journal of thoracic …, 2009 - core.ac.uk
DISCUSSION Stroke is a devastating complication of CABG. Manipulation of the aorta using
techniques such as crossclamping is thought to be a predisposing risk factor. The off-pump …

Twelve-month patency with the PAS-Port proximal connector device: a single center prospective randomized trial

J Kempfert, UT Opfermann, M Richter, T Bossert… - The Annals of thoracic …, 2008 - Elsevier
BACKGROUND: The PAS-Port (Cardica Inc, Redwood City, CA) is an automated system that
allows for the clampless anastomosis of vein grafts to the aorta. The intent of this study was …

Long Term Patency of Saphenous Vein Graft Using the Automated Proximal Anastomosis System Compared with the Hand-sewn Anastomosis System

K Ueyama, L Sakakura, A Murakami… - Kyobu geka. The …, 2020 - europepmc.org
Backgrounds: The purpose of this study was to compare the long term patency of PAS-Port
system with other hand-sewn anastomosis system. METHODS: From 2009 to 2018, a total of …

A case of ostial stenosis with the PAS-Port proximal anastomosis system in off-pump coronary artery bypass grafting

H Izutani, M Yoshitatsu, J Kawamoto… - … and Thoracic Surgery, 2005 - academic.oup.com
The use of an automatic aortic connector device for proximal saphenous vein graft
anastomoses eliminates the need for aortic clamping during off-pump coronary artery …

Assessment of an aortosaphenous vein graft anastomotic device in coronary surgery: clinical experience and early angiographic results

C Antona, R Scrofani, M Lemma, P Vanelli… - The Annals of thoracic …, 2002 - Elsevier
BACKGROUND: Until now technologic evolution in coronary bypass surgery has focused on
extracorporeal circulation, on operation without extracorporeal circulation, and on the …

Spyder™ Proximal Coronary Vein Graft Patency over Time: The SPPOT Study

JM Schussler, CH White, MA Fontes… - The Heart Surgery …, 2009 - journal.hsforum.com
Background: Clampless proximal anastomoses are associated with fewer strokes in
coronary artery bypass (CAB) graft surgery, but lack of patency of proximal grafts has been …