Accuracy and reading time for six strategies using digital breast tomosynthesis in women with mammographically negative dense breasts

AS Tagliafico, M Calabrese, B Bignotti, A Signori… - European …, 2017 - Springer
Objective To compare six strategies using digital breast tomosynthesis in women with
mammographically negative dense breasts. Materials and methods This is a substudy of the …

Digital breast tomosynthesis slab thickness: impact on reader performance and interpretation time

AC Pujara, AI Joe, SK Patterson, CH Neal… - Radiology, 2020 - pubs.rsna.org
Background Digital breast tomosynthesis (DBT) helps reduce recall rates and improve
cancer detection compared with two-dimensional (2D) mammography but has a longer …

Added value of one-view breast tomosynthesis combined with digital mammography according to reader experience

I Thomassin-Naggara, N Perrot, S Dechoux… - European journal of …, 2015 - Elsevier
Purpose To retrospectively evaluate the added value of one-view breast tomosynthesis in
adjunct with mammography to characterize breast lesions. Materials and methods Our …

[HTML][HTML] Digital breast tomosynthesis versus mammography and breast ultrasound: a multireader performance study

F Thibault, C Dromain, C Breucq, CS Balleyguier… - European …, 2013 - Springer
Objectives To compare the diagnostic performance of single-view breast tomosynthesis (BT)
with that of dual-view mammography (MX); to assess the benefit of adding the craniocaudal …

The accuracy of digital breast tomosynthesis compared with coned compression magnification mammography in the assessment of abnormalities found on …

JC Morel, A Iqbal, RK Wasan, C Peacock, DR Evans… - Clinical radiology, 2014 - Elsevier
Aim To compare the diagnostic accuracy of the digital breast tomosynthesis (DBT) with
coned compression magnification mammography (CCMM). Materials and methods The …

[HTML][HTML] Comparison of performance metrics with digital 2D versus tomosynthesis mammography in the diagnostic setting

M Bahl, S Mercaldo, CA Vijapura, AM McCarthy… - European …, 2019 - Springer
Objectives To compare performance metrics between digital 2D mammography (DM) and
digital breast tomosynthesis (DBT) in the diagnostic setting. Methods Consecutive diagnostic …

Characterization of lesions in dense breasts: Does tomosynthesis help?

K Rangarajan, S Hari, S Thulkar… - Indian Journal of …, 2016 - thieme-connect.com
Context: Mammography in dense breasts is challenging due to lesion obscuration by tissue
overlap. Does tomosynthesis offers a solution? Aims: To study the impact of digital breast …

Performance of wide-angle tomosynthesis with synthetic mammography in comparison to full field digital mammography

S Khanani, C Hruska, A Lazar, M Hoernig… - Academic radiology, 2023 - Elsevier
Rationale and Objectives The purpose of this study was to test for superiority of wide-angle
digital breast tomosynthesis plus synthetic mammography (Insight 2D) in comparison to full …

Digital breast tomosynthesis versus supplemental diagnostic mammographic views for evaluation of noncalcified breast lesions

ML Zuley, AI Bandos, MA Ganott, JH Sumkin, AE Kelly… - Radiology, 2013 - pubs.rsna.org
Purpose To compare the diagnostic performance of breast tomosynthesis versus
supplemental mammography views in classification of masses, distortions, and …

[HTML][HTML] Can digital breast tomosynthesis perform better than standard digital mammography work-up in breast cancer assessment clinic?

S Mall, J Noakes, M Kossoff, W Lee, M McKessar… - European …, 2018 - Springer
Purpose To compare the efficacy of use of digital breast tomosynthesis (DBT) with standard
digital mammography (DM) workup views in the breast cancer assessment clinic. Materials …