Evaluation of a novel Scheimpflug-based non-contact tonometer in healthy subjects and patients with ocular hypertension and glaucoma

L Reznicek, D Muth, A Kampik, AS Neubauer… - British Journal of …, 2013 - bjo.bmj.com
Background To evaluate the agreement of intraocular pressure (IOP) and central corneal
thickness (CCT) measurements obtained with the non-contact tonometer Corvis …

Repeatability of intra-ocular pressure and central corneal thickness measurements provided by a non-contact method of tonometry and pachymetry

DS Lomoriello, M Lombardo, L Tranchina… - Graefe's Archive for …, 2011 - Springer
Background To examine the repeatability of intra-ocular pressure (IOP) and central corneal
thickness (CCT) measurements provided by the Tono-Pachymeter NT530P (Nidek, Japan) …

[HTML][HTML] Varying effects of corneal thickness on intraocular pressure measurements with different tonometers

YC Ko, WM Hsu - Eye, 2005 - nature.com
Aims To compare the intraocular pressure (IOP) measurements using the Goldmann
applanation tonometer (GAT), noncontact tonometer (NCT), and ocular blood flow tonometer …

Effect of central corneal thickness on intraocular pressure and comparison of Topcon CT‐80 non‐contact tonometry with Goldmann applanation tonometry

T Mansoori, N Balakrishna - Clinical and Experimental …, 2018 - Wiley Online Library
Background To compare intraocular pressure (IOP) measurements obtained with the
Topcon CT‐80 non‐contact tonometer (NCT) and Goldmann applanation tonometer (GAT) …

Corneal deformation parameters provided by the Corvis-ST pachy-tonometer in healthy subjects and glaucoma patients

ML Salvetat, M Zeppieri, C Tosoni, M Felletti… - Journal of …, 2015 - journals.lww.com
Purpose: To evaluate precision and accuracy of Corvis-ST, a new noncontact tonometer
equipped with a high-speed Scheimpflug technology, which measures intraocular pressure …

Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow …

TA Saleh, M Adams, B McDermott… - Clinical & …, 2006 - Wiley Online Library
Purpose: To assess the effects of central corneal thickness (CCT) and corneal curvature
(CC) on the measurements of intraocular pressure (IOP) using Goldmann applanation …

The influence of central corneal thickness and corneal curvature radius on the intraocular pressure as measured by different tonometers: noncontact and goldmann …

Y Harada, N Hirose, T Kubota, A Tawara - Journal of glaucoma, 2008 - journals.lww.com
Purpose The aim of this study was to examine whether or not central corneal thickness
(CCT) and corneal curvature radius (CCR) influence the concordance of intraocular …

[HTML][HTML] Comparison of intraocular pressure as measured by three different non-contact tonometers and goldmann applanation tonometer for non-glaucomatous …

SP Bang, CE Lee, YC Kim - BMC ophthalmology, 2017 - Springer
Background To compare the measurement of intraocular pressure (IOP) among the three
different non-contact tonometers (NCT) and the Goldmann applanation tonometer (GAT) for …

The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann …

PA Tonnu, T Ho, T Newson, A El Sheikh… - British Journal of …, 2005 - bjo.bmj.com
Aims: To evaluate the influence of central corneal thickness (CCT) on intraocular pressure
(IOP) measurements made with the Goldmann applanation tonometer (GAT), Tono-Pen XL …

Comparison of intraocular pressure measurements obtained by Icare PRO rebound tonometer, Tomey FT-1000 noncontact tonometer, and Goldmann applanation …

M Güler, S Bilak, B Bilgin, A Simsek, M Çapkin… - Journal of …, 2015 - journals.lww.com
Purpose: To compare intraocular pressure (IOP) measurements obtained by Icare PRO
rebound tonometer (RT), Tomey FT-1000 noncontact tonometer (NCT), and Goldmann …