[HTML][HTML] Developing of an automation for therapy dosimetry systems by using labview software

S Aydin, E Kam - Results in Physics, 2018 - Elsevier
Traceability, accuracy and consistency of radiation measurements are essential in radiation
dosimetry, particularly in radiotherapy, where the outcome of treatments is highly dependent …

Automation of radiation dosimetry using PTW dosemeter and LabVIEW™

C Weiss, K Al-Frouh, O Anjak - … and Methods in Physics Research Section …, 2011 - Elsevier
Automation of UNIDOS “Dosemeter” using personal computer (PC) is discussed in this
paper. In order to save time and eliminate human operation errors during the radiation …

Calibration of routine dosimeters in radiation processing: validation procedure for in-plant calibration

BL Šećerov, GG Bačić - Nuclear technology and radiation protection, 2011 - doiserbia.nb.rs
The essential prerequisite of radiation dosimetry is to provide quality assurance and
documentation that the irradiation procedure has been carried out according to the …

[引用][C] Quality Assurance of the Dose Calibrator

NV Uushona, TJ Khotle - Physica Medica: European Journal of …, 2007 - physicamedica.com
Objectives The dose calibrator is the most essential instrument in nuclear medicine, for
measuring the activity of radiopharmaceutical before being administered to the patients. In …

In vivo dosimetry with diodes in a radiotherapy department in Pakistan

M Tunio, M Rafi, S Ali, Z Ahmed… - Radiation protection …, 2011 - academic.oup.com
Abstract The International Commission of Radiological Units (ICRU) sets a tolerance of±5%
on dose delivery, with more recent data limiting the overall tolerances to±3%. One of the …

Development of external dosimetry audits for advanced technology in radiotherapy dose delivery: an IAEA coordinated research project

M Tomsej, D Followill, D Georg… - … European Journal of …, 2015 - physicamedica.com
Development of external dosimetry audits for advanced technology in radiotherapy dose
delivery: An IAEA coordinated research pro Page 1 calculations and measurements was verified …

Clinical considerations and dosimeters for in vivo dosimetry

D Bollinger, A Darafsheh - Radiation Therapy Dosimetry, 2021 - taylorfrancis.com
In vivo dosimetry is a powerful tool to verify dose delivery accuracy. By placing a radiation
detector at a point of interest, we can validate that the expected dose is delivered to the …

Commissioning of Peacock System for intensity-modulated radiation therapy

CB Saw, KM Ayyangar, RB Thompson, W Zhen… - Medical …, 2001 - Elsevier
The Peacock System was introduced to perform tomographic intensity-modulated radiation
therapy (IMRT). Commissioning of the Peacock System included the alignment of the …

Humidity effects on calibrations of radiation therapy electrometers

B Downton, S Walker - Medical Physics, 2012 - Wiley Online Library
Purpose: To eliminate variation in electrometer calibration results caused by high humidity
and suboptimal connectors on the standard capacitors and to implement hardware that …

Variable transformation of calibration equations for radiation dosimetry

Y Watanabe - Physics in Medicine & Biology, 2005 - iopscience.iop.org
For radiation dosimetry, dosimetric equipment must be calibrated by using known doses.
The calibration is done to determine an equation that relates the absorbed dose to a …