Head-to-head comparison between digital and analog PET of human and phantom images when optimized for maximizing the signal-to-noise ratio from small lesions

J Salvadori, F Odille, A Verger, P Olivier, G Karcher… - EJNMMI physics, 2020 - Springer
Background Routine PET exams are increasingly performed with reduced injected activities,
leading to the use of different image reconstruction parameters than the NEMA parameters …

A practical way to improve contrast‐to‐noise ratio and quantitation for statistical‐based iterative reconstruction in whole‐body PET imaging

L Fin, P Bailly, J Daouk, ME Meyer - Medical physics, 2009 - Wiley Online Library
In whole‐body positron emission tomography (PET) imaging, the detection of small uptake
foci (ie, around two or three times the tomograph's spatial resolution) is a critical issue …

NEMA image quality phantom measurements and attenuation correction in integrated PET/MR hybrid imaging

S Ziegler, BW Jakoby, H Braun, DH Paulus, HH Quick - EJNMMI physics, 2015 - Springer
Abstract Background In integrated PET/MR hybrid imaging the evaluation of PET
performance characteristics according to the NEMA standard NU 2–2007 is challenging …

Characterization and optimization of image quality as a function of reconstruction algorithms and parameter settings in a Siemens Inveon small-animal PET scanner …

EP Visser, JA Disselhorst, MG van Lier… - Nuclear Instruments and …, 2011 - Elsevier
The image reconstruction algorithms provided with the Siemens Inveon small-animal PET
scanner are filtered backprojection (FBP), 3-dimensional reprojection (3DRP), ordered …

Point-spread function reconstructed PET images of sub-centimeter lesions are not quantitative

OL Munk, LP Tolbod, SB Hansen, TV Bogsrud - EJNMMI physics, 2017 - Springer
Background PET image reconstruction methods include modeling of resolution degrading
phenomena, often referred to as point-spread function (PSF) reconstruction. The aim of this …

SMART (SiMulAtion and ReconsTruction) PET: an efficient PET simulation-reconstruction tool

E Pfaehler, JR De Jong, RAJO Dierckx… - EJNMMI physics, 2018 - Springer
Background Positron-emission tomography (PET) simulators are frequently used for
development and performance evaluation of segmentation methods or quantitative uptake …

Investigating the use of nonattenuation corrected PET images for the attenuation correction of PET data

T Chang, RH Diab, JW Clark Jr, OR Mawlawi - Medical physics, 2013 - Wiley Online Library
Purpose: The aim of this study is to investigate the feasibility of using the nonattenuated PET
images (PET‐NAC) as a means for the AC of PET data. Methods: A three‐step iterative …

Quality control for quantitative multicenter whole‐body PET/MR studies: a NEMA image quality phantom study with three current PET/MR systems

R Boellaard, I Rausch, T Beyer, G Delso… - Medical …, 2015 - Wiley Online Library
Purpose: Integrated positron emission tomography/magnetic resonance (PET/MR) systems
derive the PET attenuation correction (AC) from dedicated MR sequences. While MR‐AC …

Reliability of predicting image signal‐to‐noise ratio using noise equivalent count rate in PET imaging

T Chang, G Chang, JW Clark Jr, RH Diab… - Medical …, 2012 - Wiley Online Library
Purpose: Several investigators have shown that noise equivalent count rate (NECR) is
linearly proportional to the square of image signal‐to‐noise ratio (SNR) when PET images …

From a PMT-based to a SiPM-based PET system: a study to define matched acquisition/reconstruction parameters and NEMA performance of the Biograph Vision 450

T Carlier, L Ferrer, M Conti, C Bodet-Milin, C Rousseau… - EJNMMI physics, 2020 - Springer
Background The purpose of this work was to propose an approach based on noise
measurement to adapt present clinical acquisition and reconstruction parameters adapted to …