Measurements of fundamental properties of homogeneous tissue phantoms
We present the optical measurement techniques used in human skin phantom studies. Their
accuracy and the sources of errors in microscopic parameters' estimation of the produced …
accuracy and the sources of errors in microscopic parameters' estimation of the produced …
Precision of measurement of tissue optical properties with optical coherence tomography
AI Kholodnykh, IY Petrova, KV Larin, M Motamedi… - Applied …, 2003 - opg.optica.org
Accurate and noninvasive measurement of tissue optical properties can be used for
biomedical diagnostics and monitoring of tissue analytes. Noninvasive measurement of …
biomedical diagnostics and monitoring of tissue analytes. Noninvasive measurement of …
New method for evaluation of in vivo scattering and refractive index properties obtained with optical coherence tomography
A Knu¨ ttel, S Bonev, W Knaak - Journal of biomedical optics, 2004 - spiedigitallibrary.org
Optical coherence tomography (OCT) provides more parameters than pure morphology
does. In a recent paper [A. Knuettel and M. Boehlau-Godau, J. Biomed. Opt. 5 (1) 83–92 …
does. In a recent paper [A. Knuettel and M. Boehlau-Godau, J. Biomed. Opt. 5 (1) 83–92 …
Measurement of optical properties of biological tissues by low-coherence reflectometry
JM Schmitt, A Knüttel, RF Bonner - Applied optics, 1993 - opg.optica.org
We show that optical properties of dense biological tissues can be determined from
backscattered power curves measured by a low-coherence reflectometer. Our measurement …
backscattered power curves measured by a low-coherence reflectometer. Our measurement …
Determination of the refractive index of highly scattering human tissue by optical coherence tomography
GJ Tearney, ME Brezinski, JF Southern, BE Bouma… - Optics letters, 1995 - opg.optica.org
We describe two new techniques, based on optical coherence tomography (OCT), for
determining the refractive index of highly scattering human tissue. We obtained refractive …
determining the refractive index of highly scattering human tissue. We obtained refractive …
Bulk optical parameters of porcine skin dermis at eight wavelengths from 325 to 1557 nm
X Ma, JQ Lu, H Ding, XH Hu - Optics letters, 2005 - opg.optica.org
We introduce a method with which to obtain accurately the bulk optical parameters of fresh
biological tissues in vitro by combining measurements of the sample surface profiles …
biological tissues in vitro by combining measurements of the sample surface profiles …
Measurements of optical tissue properties using integrating sphere technique
A Roggan - Medical optical tomography: functional imaging …, 1993 - spiedigitallibrary.org
The optical properties of white matter human brain, canine prostate and pig liver were
measured in the wavelength range 330-1100 nm. The measurements were carried out in …
measured in the wavelength range 330-1100 nm. The measurements were carried out in …
General model for depth‐resolved estimation of the optical attenuation coefficients in optical coherence tomography
We present the proof of concept of a general model that uses the tissue sample
transmittance as input to estimate the depth‐resolved attenuation coefficient of tissue …
transmittance as input to estimate the depth‐resolved attenuation coefficient of tissue …
Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography
AR Knuettel, M Boehlau-Godau - Journal of Biomedical Optics, 2000 - spiedigitallibrary.org
In the present applications of optical coherence tomography (OCT), parameters besides
pure morphology are evaluated in skin tissue under in vivo conditions. Spatially mapped …
pure morphology are evaluated in skin tissue under in vivo conditions. Spatially mapped …
Optical properties of phantoms and tissue measured in vivo from 0.9 to 1.3 um using spatially resolved diffuse reflectance
JT Bruulsema, JE Hayward, TJ Farrell… - … of Tissue: Theory …, 1997 - spiedigitallibrary.org
A near infrared spectrometer has been constructed which is capable of performing spatially
resolved diffuse reflectance measurements in the wavelength range of 0.9-1.6 micrometer …
resolved diffuse reflectance measurements in the wavelength range of 0.9-1.6 micrometer …