Identification of Streptococcus pseudopneumoniae and other mitis group streptococci using matrix assisted laser desorption/ionization-time of flight mass spectrometry
CS Jensen, R Dargis, P Shewmaker, XC Nielsen… - … and Infectious Disease, 2021 - Elsevier
This study evaluated the ability of the MALDI-ToF MS from Bruker Daltonics to identify
clinical Mitis-Group-Streptococcus isolates with a focus on Streptococcus …
clinical Mitis-Group-Streptococcus isolates with a focus on Streptococcus …
Use of MALDI Biotyper plus ClinProTools mass spectra analysis for correct identification of Streptococcus pneumoniae and Streptococcus mitis/oralis
JHK Chen, KKK She, OY Wong, JLL Teng… - Journal of Clinical …, 2015 - jcp.bmj.com
Background Differentiation of Streptococcus pneumoniae from other viridans group
streptococci is well known to be challenging in clinical laboratories. Matrix assisted laser …
streptococci is well known to be challenging in clinical laboratories. Matrix assisted laser …
[HTML][HTML] Differentiation between Streptococcus pneumoniae and other viridans group streptococci by matrix-assisted laser desorption/ionization time of flight mass …
RY Yahiaoui, WH Goessens, EE Stobberingh… - Clinical microbiology …, 2020 - Elsevier
Objectives Matrix-assisted laser desorption/ionization-time of flight mass spectrometry
(MALDI-TOF MS) is becoming the method of choice for bacterial identification. However …
(MALDI-TOF MS) is becoming the method of choice for bacterial identification. However …
Differentiation of Streptococcus pneumoniae from nonpneumococcal streptococci of the Streptococcus mitis group by matrix-assisted laser desorption ionization–time …
AM Werno, M Christner, TP Anderson… - Journal of clinical …, 2012 - Am Soc Microbiol
The differentiation of species within the Streptococcus mitis group has posed a problem in
the routine diagnostic microbiology laboratory for some time. It also constitutes a major …
the routine diagnostic microbiology laboratory for some time. It also constitutes a major …
Performance of the matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for rapid identification of streptococci: a review
WT Fan, TT Qin, RR Bi, HQ Kang, P Ma… - European Journal of …, 2017 - Springer
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)
has been developed as a new type of soft ionization mass spectrometry in recent years. An …
has been developed as a new type of soft ionization mass spectrometry in recent years. An …
[HTML][HTML] Accurate Differentiation of Streptococcus pneumoniae from other Species within the Streptococcus mitis Group by Peak Analysis Using MALDI-TOF MS
M Marín, E Cercenado, C Sánchez-Carrillo… - Frontiers in …, 2017 - frontiersin.org
Despite the benefits of MALDI-TOF MS technology (Matrix-Assisted Laser Desorption-
Ionization Time-Of-Flight Mass Spectrometry) reported worldwide and the continuous …
Ionization Time-Of-Flight Mass Spectrometry) reported worldwide and the continuous …
[HTML][HTML] Discrimination between Streptococcus pneumoniae and Streptococcus mitis based on sorting of their MALDI mass spectra
LN Ikryannikova, AV Filimonova, MV Malakhova… - Clinical Microbiology …, 2013 - Elsevier
Accurate species-level identification of alpha-hemolytic (viridans) streptococci (VGS) is very
important for understanding their pathogenicity and virulence. However, an extremely high …
important for understanding their pathogenicity and virulence. However, an extremely high …
[HTML][HTML] Identification of Streptococcus dysgalactiae using matrix-assisted laser desorption/ionization-time of flight mass spectrometry; refining the database for …
EJ Nybakken, O Oppegaard, M Gilhuus… - … and Infectious Disease, 2021 - Elsevier
Matrix-assisted laser desorption/ionization time of flight (MALDI-ToF) has revolutionized
bacterial identification. However, the phylogenetic resolution is still insufficient for discerning …
bacterial identification. However, the phylogenetic resolution is still insufficient for discerning …
Identification of clinical Streptococcus pneumoniae isolates among other alpha and nonhemolytic streptococci by use of the Vitek MS matrix-assisted laser desorption …
D Dubois, C Segonds, MF Prere, N Marty… - Journal of clinical …, 2013 - Am Soc Microbiol
Discrimination between Streptococcus pneumoniae and its close relatives of the viridans
group is a common difficulty in matrix-assisted laser desorption ionization–time of flight …
group is a common difficulty in matrix-assisted laser desorption ionization–time of flight …
Performance of the Vitek MS v2. 0 system in distinguishing Streptococcus pneumoniae from nonpneumococcal species of the Streptococcus mitis group
JA Branda, RP Markham, CD Garner… - Journal of Clinical …, 2013 - Am Soc Microbiol
The Vitek MS v2. 0 matrix-assisted laser desorption ionization–time of flight mass
spectrometry system accurately distinguished Streptococcus pneumoniae from …
spectrometry system accurately distinguished Streptococcus pneumoniae from …
相关搜索
- ionization time streptococcus pseudopneumoniae
- laser desorption rapid identification
- maldi tof streptococcus pseudopneumoniae
- maldi tof peak analysis
- nonpneumococcal streptococci streptococcus pneumoniae
- nonhemolytic streptococci streptococcus pneumoniae
- accurate differentiation streptococcus pneumoniae
- accurate differentiation peak analysis
- ionization time streptococcus dysgalactiae
- maldi tof streptococcus pneumoniae
- maldi tof accurate differentiation