Liver stiffness measurements with MR elastography: agreement and repeatability across imaging systems, field strengths, and pulse sequences
Purpose To prospectively assess agreement and repeatability of magnetic resonance (MR)
elastography liver stiffness measurements across imager manufacturers, field strengths, and …
elastography liver stiffness measurements across imager manufacturers, field strengths, and …
Cross-vendor validation of liver magnetic resonance elastography
Purpose To evaluate and validate the reproducibility of MR Elastography (MRE)-derived
liver stiffness values on two different MR vendor platforms performed on the same subject on …
liver stiffness values on two different MR vendor platforms performed on the same subject on …
Repeatability of magnetic resonance elastography for quantification of hepatic stiffness
CDG Hines, TA Bley, MJ Lindstrom… - Journal of Magnetic …, 2010 - Wiley Online Library
Purpose: To determine the sources of variability of MRE hepatic stiffness measurements
using healthy volunteers and patients and to calculate the minimum change required for …
using healthy volunteers and patients and to calculate the minimum change required for …
Magnetic resonance elastography: feasibility of liver stiffness measurements in healthy volunteers at 3 T
AIM: To demonstrate the feasibility of obtaining liver stiffness measurements with magnetic
resonance elastography (MRE) at 3T in normal healthy volunteers using the same technique …
resonance elastography (MRE) at 3T in normal healthy volunteers using the same technique …
Hepatic MR elastography: clinical performance in a series of 1377 consecutive examinations
Purpose To assess the technical success rate and diagnostic performance of liver magnetic
resonance (MR) elastography. Materials and Methods This retrospective study was …
resonance (MR) elastography. Materials and Methods This retrospective study was …
Interplatform reproducibility of liver and spleen stiffness measured with MR elastography
Purpose To assess interplatform reproducibility of liver stiffness (LS) and spleen stiffness
(SS) measured with magnetic resonance elastography (MRE) based on a 2D gradient echo …
(SS) measured with magnetic resonance elastography (MRE) based on a 2D gradient echo …
Technical failure of MR elastography examinations of the liver: experience from a large single-center study
M Wagner, I Corcuera-Solano, G Lo, S Esses, J Liao… - Radiology, 2017 - pubs.rsna.org
Purpose To assess the determinants of technical failure of magnetic resonance (MR)
elastography of the liver in a large single-center study. Materials and Methods This …
elastography of the liver in a large single-center study. Materials and Methods This …
MR elastography of healthy liver parenchyma: Normal value and reliability of the liver stiffness value measurement
Purpose To investigate the normal liver stiffness value using MR elastography (MRE) and to
compare the repeatability and reproducibility of three measurement methods. Materials and …
compare the repeatability and reproducibility of three measurement methods. Materials and …
Repeatability of MR elastography of liver: a meta-analysis
Purpose To perform a meta-analysis to generate an estimate of the repeatability coefficient
(RC) for magnetic resonance (MR) elastography of the liver. Materials and Methods A …
(RC) for magnetic resonance (MR) elastography of the liver. Materials and Methods A …
Magnetic resonance elastography of the liver: qualitative and quantitative comparison of gradient echo and spin echo echoplanar imaging sequences
Objective The aim of this study was to compare 2-dimensional (2D) gradient recalled echo
(GRE) and 2D spin echo echoplanar imaging (SE-EPI) magnetic resonance elastography …
(GRE) and 2D spin echo echoplanar imaging (SE-EPI) magnetic resonance elastography …