[HTML][HTML] 3D curved multiplanar cone beam CT reconstruction for intracochlear position assessment of straight electrodes array. A temporal bone and clinical study
SUMMARY A retrospective review of post-op cone beam CT (CBCT) of 8 adult patients and
14 fresh temporal bones that underwent cochlear implantation with straight flexible …
14 fresh temporal bones that underwent cochlear implantation with straight flexible …
Cone beam computed tomography and histological evaluations of a straight electrode array positioning in temporal bones
I Mosnier, C Célérier, JL Bensimon… - Acta Oto …, 2017 - Taylor & Francis
Conclusion: CBCT allows a precise evaluation of the dimensions and of the shape of the
cochlear duct that is of primary importance for the choice of the length and the design of the …
cochlear duct that is of primary importance for the choice of the length and the design of the …
The use of cone-beam computed tomography to determine cochlear implant electrode position in human temporal bones
SR Saeed, D Selvadurai, T Beale, N Biggs… - Otology & …, 2014 - journals.lww.com
Objective To assess the utility of cone-beam computed tomography (CBCT) imaging in the
estimation of cochlear implant (CI) electrode position in implanted temporal bones. Study …
estimation of cochlear implant (CI) electrode position in implanted temporal bones. Study …
In vivo measurements of the insertion depth of cochlear implant arrays using flat-panel volume computed tomography
A Trieger, A Schulze, M Schneider, T Zahnert… - Otology & …, 2011 - journals.lww.com
Objective: The development of a procedure for the measurement of insertion depth angles of
cochlear implant electrode arrays based on flat-panel computed tomography (FPCT) and the …
cochlear implant electrode arrays based on flat-panel computed tomography (FPCT) and the …
Scalar localization of the electrode array after cochlear implantation: clinical experience using 64-slice multidetector computed tomography
JI Lane, RJ Witte, CLW Driscoll, JK Shallop… - Otology & …, 2007 - journals.lww.com
Objective: To use the improved resolution available with 64-slice multidetector computed
tomography (MDCT) in vivo to localize the cochlear implant electrode array within the basal …
tomography (MDCT) in vivo to localize the cochlear implant electrode array within the basal …
Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis
J Teymouri, TE Hullar, TA Holden… - Otology & …, 2011 - journals.lww.com
Objective: To determine the efficacy of clinical computed tomographic (CT) imaging to verify
postoperative electrode array placement in cochlear implant (CI) patients. Study Design …
postoperative electrode array placement in cochlear implant (CI) patients. Study Design …
Intraoperative conebeam CT for assessment of intracochlear positioning of electrode arrays in adult recipients of cochlear implants
BACKGROUND AND PURPOSE: Intraoperative conebeam CT has been introduced into the
operating room and provides quick radiologic feedback. This study aimed to investigate its …
operating room and provides quick radiologic feedback. This study aimed to investigate its …
Diagnostic role of cone beam computed tomography for the position of straight array
Objective: To assess the usefulness of cone beam computed tomography (CBCT) for
characterizing electrode insertion and evaluate the influence of electrode insertion status on …
characterizing electrode insertion and evaluate the influence of electrode insertion status on …
Scalar localization of the electrode array after cochlear implantation: a cadaveric validation study comparing 64-slice multidetector computed tomography with …
JI Lane, CLW Driscoll, RJ Witte, A Primak… - Otology & …, 2007 - journals.lww.com
Background: In CI surgery, the electrode array should be inserted into and remain within the
scala tympani to avoid injury to Reissner's membrane and the scala media. Correlating the …
scala tympani to avoid injury to Reissner's membrane and the scala media. Correlating the …
Imaging cochlear implantation with round window insertion in human temporal bones and cochlear morphological variation using high-resolution cone beam CT
J Zou, J Lähelmä, J Koivisto, A Dhanasingh… - Acta oto …, 2015 - Taylor & Francis
Conclusions: The present experimental set-up of high spatial resolution cone-beam
computed tomography (CBCT) showed advantages of demonstrating the critical landmarks …
computed tomography (CBCT) showed advantages of demonstrating the critical landmarks …