Valve‐in‐valve‐in‐valve: Balloon expandable transcatheter heart valve in failing self‐expandable transcatheter heart valve in deteriorated surgical bioprosthesis

A Schaefer, F Deuschl, L Conradi… - Catheterization and …, 2018 - Wiley Online Library
Abstract Valve‐in‐valve (ViV) procedures for failing bioprostheses carry a certain risk for
device malfunction. We herein report a case of a failing Evolut R in a deteriorated Mitroflow …

Valve-in-valve: Estimating the risk of ostium obstruction in failed sorin stentless valves

O Stanger, F Gisler, MC Londono - The Journal of thoracic and …, 2015 - jtcvs.org
Transcatheter heart valve aortic valve-in-valve (ViV) implantation is likely to become
increasingly important for the treatment of patients with degenerated and failing …

A staged approach to transcatheter aortic valve implantation and mitral valve-in-valve implantation for a degenerated bioprosthesis in a high-risk patient

G Santarpino, T Fischlein, G Concistrè… - … and thoracic surgery, 2012 - academic.oup.com
Recently, small case series have described the successful off-label use of transcatheter
valve implantation in patients with degenerated bioprosthetic valves in the mitral position …

Left ventricular outflow tract obstruction of double valve re-replacement using bioprosthesis

Y Araki, C Teramoto, Y Konishi, T Terada… - Annals of Thoracic and …, 2021 - jstage.jst.go.jp
We present a case of left ventricular outflow tract (LVOT) obstruction after double valve re-
replacement with bioprostheses. A 72-year-old man, who had undergone double valve …

Impact of pre-existing prosthesis-patient mismatch on survival following aortic valve-in-valve procedures

P Pibarot, M Simonato, M Barbanti, A Linke… - JACC: Cardiovascular …, 2018 - jacc.org
Objectives: The aim of this study was to determine whether the association of small label
size of the surgical valve with increased mortality after transcatheter valve-in-valve (ViV) …

[HTML][HTML] Transcatheter valve-in-valve implantation for degenerated surgical bioprostheses

DJ Murdoch, JG Webb - Journal of thoracic disease, 2018 - ncbi.nlm.nih.gov
Transcatheter valve-in-valve (VIV) procedures are less invasive than re-do open heart
surgery, and have proven relatively safe and effective. In large multicentre registries …

Transcatheter aortic and mitral valve implantation in bioprosthetic valves: when one correction is not enough

AC Akujuo, SL Dellis, AJ Delago, EV Bennett - The Journal of Thoracic and …, 2015 - jtcvs.org
Aortic bioprosthesis failure in high-risk patients who are not candidates for operation has
been ameliorated with transcatheter aortic valve replacement. As of last year, more than …

Long-term results of the Mitroflow aortic pericardial bioprosthesis in over 800 patients: limited durability and mechanisms of dysfunction

F Ius, J Schulz, M Roumieh, F Fleissner… - European Journal of …, 2017 - academic.oup.com
OBJECTIVES: The Mitroflow aortic pericardial bioprosthesis was widely employed in the
past. However, some authors have recently reported early structural valve deterioration …

Bailout balloon predilatation and buddy wire technique for crossing a degenerated sutureless Perceval bioprosthesis with SAPIEN 3 Ultra device in a transcatheter …

E Koni, G Trianni, M Ravani, T Gasbarri… - Cardiovascular …, 2019 - Elsevier
3. Discussion VIV is a good alternative treatment for degenerated surgical bioprostheses but
exhibits some challenges when compared to TAVI in native valves. First, especially in those …

TCT-160 valve-in-valve transcatheter aortic implantation in degenerative sutureless bioprostheses

U Landes, D Dvir, W Schoels, C Tron… - Journal of the American …, 2017 - jacc.org
Background Transcatheter valve-in-valve implantation (ViV) has evolved as a viable strategy
in suitable cases of patients with a failed surgical bioprosthesis heat valves (SHV) …