Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction

MC Maas, DR Schaart, DJJ van der Laan… - Physics in Medicine …, 2009 - iopscience.iop.org
We developed positron emission tomography (PET) detectors based on monolithic
scintillation crystals and position-sensitive light sensors. Intrinsic depth-of-interaction (DOI) …

A practical method for depth of interaction determination in monolithic scintillator PET detectors

HT Van Dam, S Seifert, R Vinke… - Physics in Medicine …, 2011 - iopscience.iop.org
Several new methods for determining the depth of interaction (DOI) of annihilation photons
in monolithic scintillator detectors with single-sided, multi-pixel readout are investigated. The …

Monolithic LaBr3: Ce crystals on silicon photomultiplier arrays for time-of-flight positron emission tomography

S Seifert, HT van Dam, J Huizenga… - Physics in Medicine …, 2012 - iopscience.iop.org
Positron emission tomography detectors based on monolithic scintillation crystals exhibit
good spatial and energy resolution, intrinsically provide depth-of-interaction information …

Towards a continuous crystal APD-based PET detector design

P Bruyndonckx, C Lemaître, D Schaart, M Maas… - Nuclear Instruments and …, 2007 - Elsevier
Monolithic scintillator blocks provide an efficient way to significantly increase the sensitivity
of high-resolution positron emission tomography (PET) systems. Using statistical or neural …

A new method for depth of interaction determination in PET detectors

M Pizzichemi, G Stringhini, T Niknejad… - Physics in Medicine …, 2016 - iopscience.iop.org
A new method for obtaining depth of interaction (DOI) information in PET detectors is
presented in this study, based on sharing and redirection of scintillation light among multiple …

Evolution of PET detectors and event positioning algorithms using monolithic scintillation crystals

A Gonzalez-Montoro, AJ Gonzalez… - … on Radiation and …, 2021 - ieeexplore.ieee.org
The use of monolithic scintillator-based photon detectors in positron emission tomography
(PET) has emerged as an attractive alternative to traditional pixelated array designs …

High-resolution time-of-flight PET detector with 100 ps coincidence time resolution using a side-coupled phoswich configuration

MS Lee, JW Cates, A Gonzalez-Montoro… - Physics in Medicine & …, 2021 - iopscience.iop.org
Photon time-of-flight (TOF) capability in positron emission tomography (PET) enables
reconstructed image signal-to-noise ratio (SNR) improvement. With the coincidence time …

Timing evaluation of a PET detector block based on semi‐monolithic LYSO crystals

N Cucarella, J Barrio, E Lamprou, C Valladares… - Medical …, 2021 - Wiley Online Library
Purpose Detectors for positron emission tomography (PET) typically use two types of
scintillation crystals, pixelated or monolithic. A variant of these types of scintillators are the so …

A semi‐monolithic detector providing intrinsic DOI‐encoding and sub‐200 ps CRT TOF‐capabilities for clinical PET applications

F Mueller, S Naunheim, Y Kuhl, D Schug… - Medical …, 2022 - Wiley Online Library
Background Current clinical positron emission tomography (PET) systems utilize detectors
where the scintillator typically contains single elements of 3–6‐mm width and about 20‐mm …

First characterization of a digital SiPM based time-of-flight PET detector with 1 mm spatial resolution

S Seifert, G Van der Lei, HT Van Dam… - Physics in Medicine & …, 2013 - iopscience.iop.org
Monolithic scintillator detectors can offer a combination of spatial resolution, energy
resolution, timing performance, depth-of-interaction information, and detection efficiency that …