Effects of interimplant distance and cyclic dislodgement on retention of LOCATOR and ball attachments: an in vitro study

R Salehi, SS Shayegh, WM Johnston… - The Journal of Prosthetic …, 2019 - Elsevier
Statement of problem Evaluation of the long-term retentive behavior of overdenture
attachments is necessary for successful treatment. Interimplant distance (IID) could affect the …

Effect of Interimplant Distance and Cyclic Loading on the Retention of Overdenture Attachments.

SS Shayegh, SMR Hakimaneh… - The Journal of …, 2017 - europepmc.org
AIM: The purpose of this in vitro study was to investigate the effect of interimplant distance
and cyclic loading on the retention of two locator attachment systems. MATERIALS AND …

The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system

SA Al-Ghafli, KX Michalakis, H Hirayama… - Journal of Prosthetic …, 2009 - thejpd.org
Purpose. The purpose of this in vitro study was to investigate the effect of cyclic
dislodgement on the retention of an overdenture attachment system when 2 implants were …

Dislodgement force analysis of an overdenture attachment system

B Yilmaz, E Ozkir, WM Johnston… - The Journal of Prosthetic …, 2020 - Elsevier
Statement of problem The performance of a recently introduced overdenture attachment
system after cyclic dislodgement is not known. Purpose The purpose of this in vitro study …

In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures.

P Eren Türk, O Geckili, Y Türk… - … Journal of Oral & …, 2014 - search.ebscohost.com
Purpose: To compare the retentive properties of ball and locator attachments during 5,000
insertion-separation cycles, corresponding to approximately 4.5 years of clinical use …

In vitro retention force changes during cyclic dislodging of three novel attachment systems for implant overdentures with different implant angulations

S Maniewicz, I Badoud, FR Herrmann… - Clinical oral implants …, 2020 - Wiley Online Library
Objectives This in vitro study aimed to compare changes in retentive force due to cyclic
dislodging of three novel un‐splinted attachments. Materials and Methods Experimental …

The influences of implant angulations in one and two directions on the retentive properties of overdenture attachments: an in vitro study

P Atashrazm, MH Dashti, LZ Alavijeh… - The Journal of Indian …, 2014 - Springer
Implant alignment is an important factor in overdentures retained by solitary abutments. In
this study, the effect of implant angulations in two directions, on the amount of retention of …

Influence of implant angulation and cyclic dislodging on the retentive force of two different overdenture attachments – an in vitro study

M Srinivasan, M Schimmel, I Badoud… - Clinical oral implants …, 2016 - Wiley Online Library
Objective This in vitro study evaluated the influence of implant angulations on the retentive
behavior of two overdenture attachments during cyclic dislodging. Methods Models …

The change in retentive values of locator attachments and hader clips over time

E Evtimovska, R Masri, CF Driscoll… - … : Implant, Esthetic and …, 2009 - Wiley Online Library
Purpose: The aim of this study was to examine early changes in retentive values of implant
overdenture attachments during multiple pulls. Materials and Methods: Two implant …

Retention of implant‐supported overdentures at different implant angulations: Comparing Locator and ball attachments

N Sultana, DW Bartlett… - Clinical oral implants …, 2017 - Wiley Online Library
Objectives To assess the effect of implant angulation on the retention of two different
attachment systems for implant‐supported overdentures after a simulated fatigue period of …