The incidence of complications in elective cranial neurosurgery associated with dural closure material

BP Walcott, JB Neal, SA Sheth, KT Kahle… - Journal of …, 2014 - thejns.org
Object Dural closure with synthetic grafts has been suggested to contribute to the incidence
of infection and CSF leak. The objective of this study was to assess the contribution of choice …

[引用][C] Dural repair after craniotomy and the use of dural substitutes and dural sealants.

LN Sekhar, JC Mai - World Neurosurgery, 2011 - europepmc.org
Dural repair after craniotomy and the use of dural substitutes and dural sealants. - Abstract -
Europe PMC Sign in | Create an account https://orcid.org Europe PMC Menu About Tools …

Dural augmentation: part I—evaluation of collagen matrix allografts for dural defect after craniotomy

ZN Litvack, GA West, JB Delashaw, KJ Burchiel… - …, 2009 - journals.lww.com
OBJECTIVE: Primary closure of the dura remains difficult in many neurosurgical cases. One
option for dural grafting is the collagen sponge, which is available in multiple forms, namely …

The safety and effectiveness of a dural sealant system for use with nonautologous duraplasty materials

JS Weinstein, KC Liu, JB Delashaw, KJ Burchiel… - Journal of …, 2010 - thejns.org
Object The DuraSeal dural sealant system, a polyethylene glycol hydrogel, has been shown
to be safe and effective when used with commercial and autologous duraplasty materials …

Comparison of deep wound infection rates using a synthetic dural substitute (neuro-patch) or pericranium graft for dural closure: a clinical review of 1 year

M Malliti, P Page, C Gury, E Chomette, F Nataf… - …, 2004 - journals.lww.com
OBJECTIVE: The need to repair dural defects has prompted the use of dura mater
substitutes. Many synthetic materials have been used for dural closure. Neuro-Patch (B …

[HTML][HTML] Efficacy and safety of polyethylene glycol dural sealant system in cranial and spinal neurosurgical procedures: Meta-analysis

A Diab, H Al-Shami, A Negida, A Gadallah… - Surgical Neurology …, 2021 - ncbi.nlm.nih.gov
Background: We aimed to assess the efficacy of polyethylene glycol (PEG) dura sealant to
achieve watertight closure, prevention of cerebrospinal fluid (CSF) leak and to investigate its …

[HTML][HTML] A Case Series of DuraMatrix-Onlay® Plus in Cranial Surgery Is Associated With a Low Complication Profile

M Mekonnen, G Hovis, N Mahgerefteh… - Brain tumor research …, 2023 - ncbi.nlm.nih.gov
Background DuraMatrix-Onlay® Plus is a collagen dura membrane derived from purified
bovine Achilles tendon. The matrix provides a scaffold for collagen synthesis and is intended …

Identification of risk factors for postoperative cerebrospinal fluid leakage and comparison of two alternative dural augmentation techniques in posterior fossa and …

M Eser, S Hanalioglu, M Cetiner… - Turkish …, 2019 - avesis.lokmanhekim.edu.tr
© 2019 Turkish Neurosurgical Society. AIM: To investigate comparative efficacy of a novel
absorbable adhesive membrane (TissuePatchDuralTM'TPD') and a fibrin glue (Tisseel'T') in …

[HTML][HTML] Risk factors for cerebrospinal fluid leakage after craniotomy and the efficacy of dural sealants application versus dural suturing alone

BJ Ha, JH Cheong, HJ Yi - The Nerve, 2016 - thenerve.net
Objective Cerebrospinal fluid (CSF) leakage is a latent risk of cranial surgery with dural
opening. We hypothesize that addition of Duraform on top of dural suture reduces …

Postoperative complications associated with dural substitutes in suboccipital craniotomies

SI Moskowitz, J Liu, AA Krishnaney - Operative Neurosurgery, 2009 - journals.lww.com
OBJECTIVE: Dural replacements are used in cranial surgery when primary closure of native
dura is not possible. The goal is to recreate a watertight barrier to prevent cerebrospinal fluid …