Ischemia-modified albumin concentrations in patients with peripheral vascular disease and exercise-induced skeletal muscle ischemia

D Roy, J Quiles, R Sharma, M Sinha… - Clinical …, 2004 - academic.oup.com
Background: Ischemia-modified albumin (IMA) is a new marker of myocardial ischemia,
there is concern that IMA concentrations may be affected by ischemia occurring in tissues …

Ischemia-modified albumin in relation to exercise stress testing

E Sbarouni, P Georgiadou, GN Theodorakis… - Journal of the American …, 2006 - jacc.org
Objectives: We examined whether ischemia-modified albumin (IMA) plasma levels change
during exercise stress testing (EST) in patients with known coronary artery disease and …

Ischemia-modified albumin during skeletal muscle ischemia

E Zapico-Muñiz, M Santaló-Bel… - Clinical …, 2004 - academic.oup.com
Ischemia-modified albumin (IMA) has been proposed as a biological marker of myocardial
ischemia (1, 2). Exposure to ischemic myocardium modifies circulating albumin at its NH2 …

Serum levels of ischemia-modified albumin in healthy volunteers after exercise-induced calf-muscle ischemia

J Falkensammer, T Stojakovic, K Huber… - 2007 - degruyter.com
Background: Ischemia-modified albumin (IMA) is an emerging marker of ischemia. To
investigate the applicability of IMA for the diagnosis of skeletal muscle ischemia, we …

Ischemia modified albumin: a novel biomarker for the detection of cardiac ischemia

DC Gaze - Drug metabolism and pharmacokinetics, 2009 - Elsevier
The diagnosis of cardiac ischemia remains a challenge in contemporary emergency
medicine. A blood-borne biomarker is an attractive alternative to cardiac imaging or stress …

High-workload endurance training may increase serum ischemia-modified albumin concentrations

G Lippi, G Brocco, GL Salvagno, M Montagnana… - 2005 - degruyter.com
The measurement of cardiac troponins has emerged as the biochemical “gold standard” for
the diagnosis and management of patients with acute chest pain. However, earlier markers …

Ischemia-modified albumin in stable coronary atherosclerotic heart disease: clinical diagnosis and risk stratification

Y Zhong, N Wang, H Xu, X Hou, P Xu… - Coronary Artery …, 2012 - journals.lww.com
Objectives Ischemia-modified albumin (IMA), a new serum biomarker of myocardial
ischemia, has been introduced in the diagnosis of acute coronary syndrome. However, few …

[HTML][HTML] Ischaemic skeletal muscle increases serum ischaemia modified albumin

M Troxler, D Thompson… - European journal of …, 2006 - Elsevier
OBJECTIVES: Ischaemia modified albumin (IMA) has been used as a marker of myocardial
ischaemia but little is known about its production during ischaemia of other tissues. The …

Evaluation of ischemia-modified albumin in myocardial infarction and prostatic diseases

AK Mastella, RN Moresco, DB da Silva… - Biomedicine & …, 2009 - Elsevier
BACKGROUND: Ischemia-modified albumin (IMA) has been shown to be a rapidly rising
and sensitive biochemical marker for the diagnosis of myocardial ischemia. In this study, we …

Ischemia-modified albumin concentrations should be interpreted with caution in patients with low serum albumin concentrations

DC Gaze, L Crompton, P Collinson - Medical Principles and Practice, 2006 - karger.com
Objective: Ischemia-modified albumin (IMA®) is a novel marker for assessing cardiac
ischaemia. We assessed the relationship between total albumin concentrations and IMA in …