Monte Carlo and TLD dosimetry of an high dose‐rate brachytherapy source

P Karaiskos, A Angelopoulos, L Sakelliou… - Medical …, 1998 - Wiley Online Library
An analytical Monte Carlo simulation code has been used to perform dosimetry calculations
around an high dose‐rate brachytherapy source utilized in the widely used microSelectron …

Monte Carlo‐aided dosimetry of a new high dose‐rate brachytherapy source

GM Daskalov, E Löffler, JF Williamson - Medical physics, 1998 - Wiley Online Library
In this article we introduce a new high‐intensity source design for use in a recently
reengineered microSelectron‐HDR remote afterloading device for high dose‐rate (HDR) …

Monte Carlo dosimetry of a new pulsed dose rate brachytherapy source

P Karaiskos, A Angelopoulos, E Pantelis… - Medical …, 2003 - Wiley Online Library
A new microSelectron pulsed dose rate source has been designed, containing two active
pellets instead of one inactive and one active pellet contained in the old design, to facilitate …

Monte Carlo dosimetry of HDR brachytherapy sources

P Papagiannis, A Angelopoulos, E Pantelis… - Medical …, 2003 - Wiley Online Library
Monte Carlo based dosimetry is presented for three HDR sources with a unique
configuration of two active pellets in contact or spaced 9 and 11 mm apart. Results are …

Phantom size in brachytherapy source dosimetric studies

J Pérez‐Calatayud, D Granero, F Ballester - Medical physics, 2004 - Wiley Online Library
An important point to consider in a brachytherapy dosimetry study is the phantom size
involved in calculations or experimental measurements. As pointed out by Williamson [Med …

TLD, diode and Monte Carlo dosimetry of an 192Ir source for high dose-rate brachytherapy

AS Kirov, JF Williamson, AS Meigooni… - Physics in Medicine & …, 1995 - iopscience.iop.org
Very few dosimetry data are available for the current generation of high-dose-rate (HDR)
192 Ir sources, which have broad application in remotely afterloaded brachytherapy. The …

A Monte Carlo investigation of the dosimetric characteristics of the VariSource high dose rate brachytherapy source

P Karaiskos, A Angelopoulos, P Baras… - Medical …, 1999 - Wiley Online Library
An analytical Monte Carlo simulation code, incorporating in detail source construction and
dimensions, was used to investigate the dosimetric characteristics of the VariSource high …

Monte Carlo and experimental dosimetry of an brachytherapy seed

J Dolan, Z Li, JF Williamson - Medical physics, 2006 - Wiley Online Library
We have performed a comprehensive dosimetric characterization of the model 6711 seed
using both experimental [thermoluminscent dosimetry (TLD)] and theoretical (Monte Carlo …

An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo‐based brachytherapy dose distributions a

MJ Rivard, CS Melhus, D Granero… - Medical …, 2009 - Wiley Online Library
Certain brachytherapy dose distributions, such as those for LDR prostate implants, are
readily modeled by treatment planning systems (TPS) that use the superposition principle of …

EGSnrc Monte Carlo calculated dosimetry parameters for and brachytherapy sources

REP Taylor, DWO Rogers - Medical physics, 2008 - Wiley Online Library
This study presents the results of EGSnrc Monte Carlo calculations of the dose distribution
surrounding a high dose rate brachytherapy source and 14 high dose rate and pulsed dose …