A Monte Carlo dose calculation algorithm for proton therapy

M Fippel, M Soukup - Medical physics, 2004 - Wiley Online Library
A Monte Carlo (MC) code (VMCpro) for treatment planning in proton beam therapy of cancer
is introduced. It is based on ideas of the Voxel Monte Carlo algorithm for photons and …

Range uncertainties in proton therapy and the role of Monte Carlo simulations

H Paganetti - Physics in Medicine & Biology, 2012 - iopscience.iop.org
The main advantages of proton therapy are the reduced total energy deposited in the patient
as compared to photon techniques and the finite range of the proton beam. The latter adds …

Monte Carlo dose calculations for spot scanned proton therapy

A Tourovsky, AJ Lomax, U Schneider… - Physics in Medicine & …, 2005 - iopscience.iop.org
Density heterogeneities can have a profound effect on dose distributions for proton therapy.
Although analytical calculations in homogeneous media are relatively straightforward, the …

Monte Carlo simulations for configuring and testing an analytical proton dose-calculation algorithm

W Newhauser, J Fontenot, Y Zheng, J Polf… - Physics in Medicine …, 2007 - iopscience.iop.org
Contemporary treatment planning systems for proton radiotherapy typically use analytical
pencil-beam algorithms—which require a comprehensive set of configuration data—to …

Monte Carlo calculations for absolute dosimetry to determine machine outputs for proton therapy fields

H Paganetti - Physics in Medicine & Biology, 2006 - iopscience.iop.org
The prescribed dose in radiation therapy has to be converted into machine monitor units for
patient treatment. This is done routinely for each spread-out Bragg peak (SOBP) field either …

Site-specific range uncertainties caused by dose calculation algorithms for proton therapy

J Schuemann, S Dowdell, C Grassberger… - Physics in Medicine …, 2014 - iopscience.iop.org
The purpose of this study was to assess the possibility of introducing site-specific range
margins to replace current generic margins in proton therapy. Further, the goal was to study …

Comparison of Monte Carlo and analytical dose computations for intensity modulated proton therapy

P Yepes, A Adair, D Grosshans… - Physics in Medicine …, 2018 - iopscience.iop.org
To evaluate the effect of approximations in clinical analytical calculations performed by a
treatment planning system (TPS) on dosimetric indices in intensity modulated proton …

Dose to water versus dose to medium in proton beam therapy

H Paganetti - Physics in medicine & biology, 2009 - iopscience.iop.org
Dose in radiation therapy is traditionally reported as the water-equivalent dose, or dose to
water. Monte Carlo dose calculations report dose to medium and thus a methodology is …

Monte Carlo modelling of the treatment line of the Proton Therapy Center in Orsay

A Stankovskiy, S Kerhoas-Cavata… - Physics in Medicine …, 2009 - iopscience.iop.org
This paper presents the main results of a Monte Carlo simulation describing the Orsay
Proton Therapy Center (CPO) beam line. The project aimed to obtain a prediction of the …

Experimental evaluation of validity of simplified Monte Carlo method in proton dose calculations

R Kohno, Y Takada, T Sakae… - Physics in Medicine …, 2003 - iopscience.iop.org
It is important for proton therapy to calculate dose distributions accurately in treatment
planning. Dose calculations in the body for treatment planning are converted to dose …