Multicenter trial of ionic versus nonionic contrast media for cardiac angiography

JA Hill, M Winniford, MB Cohen, DB Van Fossen… - The American journal of …, 1993 - Elsevier
Contrast agents used for cardiac anglography are different in regard to ionicity, osmolality
and physiologic effects. The nonionic contrast media have been shown to have less toxic …

A comparison of low-with high-osmolality contrast agents in cardiac angiography. Identification of criteria for selective use.

WH Matthai Jr, WG Kussmaul 3rd, J Krol, JE Goin… - Circulation, 1994 - Am Heart Assoc
BACKGROUND Controversy exists as to whether low-osmolality radiographic contrast
agents, which have less detrimental pharmacological effects but are considerably more …

[HTML][HTML] Safety and cost effectiveness of high-osmolality as compared with low-osmolality contrast material in patients undergoing cardiac angiography

EP Steinberg, RD Moore, NR Powe… - … England Journal of …, 1992 - Mass Medical Soc
Abstract Background and Methods. Low-osmolality contrast agents produce fewer
hemodynamic and electrophysiologic alterations during cardiac angiography, but they are …

Comparison of an ionic with a nonionic contrast agent for cardiac angiography: results of a multicenter trial

MA BETTMANN, CB HIGGINS - Investigative radiology, 1985 - journals.lww.com
Ionic contrast agents currently used in cardiac angiography are well tolerated but have
certain negative effects. In a five-center study of 273 patients undergoing cardiac …

Iodixanol, a new isosmotic nonionic contrast agent compared with iohexol in cardiac angiography

JA Hill, MB Cohen, WH Kou, GBJ Mancini… - The American journal of …, 1994 - Elsevier
Iodixanol, a new ratio 6 nonionic iodinated contrast agent with an osmolality equal to serum,
was compared with iohexol in a randomized, double-blind, parallel study. Two hundred …

Safety of cardiac angiography with conventional ionic contrast agents

JW Hirshfeld Jr, WG Kussmaul, PM DiBattiste - The American journal of …, 1990 - Elsevier
To characterize the frequency of adverse reactions to conventional ionic contrast agents,
data describing the frequency of such reactions were gathered from 4,630 diagnostic …

Comparison of cardiovascular and renal toxicity after cardiac catheterization using a nonionic versus ionic radiographic contrast agent

MB Harding, CJ Davidson, KS Pieper, M Hlatky… - The American journal of …, 1991 - Elsevier
Both ionic and nonionic contrast agents used in angiography are relatively well tolerated but
have a number of undesirable effects, particularly on the cardiovascular system and the …

Nephrotoxicity of ionic and nonionic contrast media in 1196 patients: a randomized trial

MR Rudnick, S Goldfarb, L Wexler, PA Ludbrook… - Kidney international, 1995 - Elsevier
Nephrotoxicity of ionic and nonionic contrast media in 1196 patients: A randomized trial. The
incidence of nephrotoxicity occurring with the nonionic contrast agent, iohexol, and the ionic …

Cardiotolerance of iohexol: survey of experimental evidence

CB HIGGINS - Investigative Radiology, 1985 - journals.lww.com
The risk of significant complications from contrast media is greatest in angiocardiography.
Contrast media effects on central cardiovascular function include electrophysiologic effects …

Thrombotic and cardiovascular complications related to nonionic contrast media during cardiac catheterization: analysis of 8,517 patients

CJ Davidson, DB Mark, KS Pieper, KB Kisslo… - The American journal of …, 1990 - Elsevier
The incidence of major complications associated with nonionic contrast media has not been
defined in a large study. Accordingly, cardiovascular complications, especially thrombotic …