Recent developments on X-ray phase contrast imaging technology at CSEM

C Kottler, V Revol, R Kaufmann, C Urban… - AIP Conference …, 2012 - pubs.aip.org
X-ray phase contrast imaging (XPCi) using the Talbot-Lau grating interferometer attracts
increasing attention for its implementation in various fields of applications such as in the (bio …

Simulation and measurement of grating-based X-ray phase-contrast imaging

P Bartl, F Bayer, J Durst, W Haas, T Michel… - Nuclear Instruments and …, 2011 - Elsevier
In this paper we present results from simulations on grating-based phase contrast imaging.
Herein, the performance of a grating-based interferometer concerning the X-ray's energy is …

Optimization of X-ray phase contrast imaging system toward high-sensitivity measurements of biological organs

M Hoshino, K Uesugi, N Yagi - AIP Conference Proceedings, 2012 - aip.scitation.org
X-ray phase contrast imaging and tomography using a Talbot grating interferometer is
currently available for user experiments at BL20B2 in SPring-8. The measurement condition …

Non-absorption grating approach for x-ray phase contrast imaging

Y Du, X Liu, Y Lei, J Guo, H Niu - Optics express, 2011 - opg.optica.org
we demonstrate a non-absorption grating approach for X-ray phase contrast imaging based-
on grating interferometry. This technique overcomes the limitations imposed by absorption …

Inverse geometry for grating-based x-ray phase-contrast imaging

T Donath, M Chabior, F Pfeiffer, O Bunk… - Journal of Applied …, 2009 - pubs.aip.org
Phase-contrast imaging using conventional polychromatic x-ray sources and grating
interferometers has been developed and demonstrated for x-ray energies up to 60 keV …

Grating interferometer based scanning setup for hard x-ray phase contrast imaging

C Kottler, F Pfeiffer, O Bunk, C Grünzweig… - Review of Scientific …, 2007 - pubs.aip.org
In x-ray radiography, particularly for technical and industrial applications, a scanning setup
is very often favorable when compared to a direct two-dimensional image acquisition. Here …

Measurements and simulations analysing the noise behaviour of grating-based X-ray phase-contrast imaging

T Weber, P Bartl, J Durst, W Haas, T Michel… - Nuclear Instruments and …, 2011 - Elsevier
In the last decades, phase-contrast imaging using a Talbot–Lau grating interferometer is
possible even with a low-brilliance X-ray source. With the potential of increasing the soft …

High energy x-ray phase-contrast imaging using glancing angle grating interferometers

D Stutman, JW Stayman, M Finkenthal… - … 2013: Physics of …, 2013 - spiedigitallibrary.org
The Talbot-Lau grating interferometer enables refraction based imaging with conventional X-
ray tubes, offering the promise of a new medical imaging modality. The fringe contrast of the …

X-ray phase-contrast radiography using a filtered white beam with a grating interferometer

V Altapova, J Butzer, TS Rolo, P Vagovic… - Nuclear Instruments and …, 2011 - Elsevier
One of the most promising methods of phase-contrast imaging is the Talbot grating
interferometry. We report about the optimization of the method for fast imaging, requiring …

Experimental realisation of high-sensitivity laboratory X-ray grating-based phase-contrast computed tomography

L Birnbacher, M Willner, A Velroyen, M Marschner… - Scientific reports, 2016 - nature.com
The possibility to perform high-sensitivity X-ray phase-contrast imaging with laboratory
grating-based phase-contrast computed tomography (gbPC-CT) setups is of great interest …