Preliminary In Vitro Study on O-Ring Wear in Mini-Implant-Retained Overdentures.

CA Chaves, RF Souza, TR Cunha… - The International …, 2016 - europepmc.org
This preliminary in vitro study evaluated the simulated retention force of O-rings used for
mini-implant overdenture treatment and the effect of mechanical fatigue corresponding to 6 …

Retention force and deformation of an innovative attachment model for mini-implant–retained overdentures

MLC Valente, MVW Shimano, JAM Agnelli… - The Journal of prosthetic …, 2019 - Elsevier
Statement of problem The gradual loss of retention and the need for periodic replacement of
attachment-system components are the most frequent complications in implant-supported …

Mandibular overdentures retained by two mini‐implants: a seven‐year retention and satisfaction study

A Catalán, A Martínez, F Marchesani… - Journal of …, 2016 - Wiley Online Library
Purpose Patients with atrophic edentulous ridges generally have problems with retention,
therapeutic satisfaction, and comfort with their complete dentures. An alternative treatment to …

The Effect of Mini Dental Implant Number on Mandibular Overdenture Retention and Attachment Wear

R Alshenaiber, C Barclay… - BioMed Research …, 2023 - Wiley Online Library
Purpose. Evaluate the effect of different mini‐implant numbers on overdenture retention and
evaluate attachment wear following one year of simulated placement/removal. Material and …

Patient satisfaction and prosthetic aspects with mini‐implants retained mandibular overdentures. A 5‐year prospective study

MA Elsyad - Clinical Oral Implants Research, 2016 - Wiley Online Library
Purpose This study aimed to evaluate patient satisfaction and prosthetic aspects during a 5‐
year prospective clinical study of mini dental implants (MDI s) retaining mandibular …

Lateral forces exerted through ball or bar attachments in relation to the inclination of mini‐implant underneath overdentures: in vitro study

K Takagaki, T Gonda, Y Maeda - Clinical oral implants research, 2015 - Wiley Online Library
Objective Lateral force to mini‐implants should be avoided because mini‐implants are weak
mechanically because of its small diameter. Overdentures retained by mini‐implants are …

Immediate Loading of Mandibular Overdentures Retained by Two Mini-Implants: A Case Series Preliminary Report.

E Bellia, L Boggione, M Terzini… - International …, 2018 - search.ebscohost.com
Abstract < bold> Purpose: </bold> This preliminary case series report sought to
evaluate the efficacy of an immediate loading protocol for mandibular overdentures retained …

Clinical performance and material properties of single-implant overdenture attachment systems.

NHM Alsabeeha, MV Swain… - International Journal of …, 2011 - search.ebscohost.com
Purpose: The aim of this study was to evaluate the mechanical properties of different
attachment systems used for mandibular single-implant overdentures and to compare their …

[PDF][PDF] The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: 6-month fatigue retention …

D Doukas, G Michelinakis, PW Smith… - International journal of …, 2008 - crete-implants.com
Materials and Methods The type, sample size, and specifications of the attachment pairs
used in this in vitro study are shown in Table 1. All pairs were tested at IDs of 19, 23, and 29 …

New mini dental implant attachments versus O-ring attachment after cyclic aging: Analysis of retention strength and gap space

AA Fatalla, K Song, Y Cao - Journal of Huazhong University of Science …, 2017 - Springer
Overdenture as a treatment modality for both partially and fully edentulous patients is
costeffective and less expensive. The purpose of the present study was to examine the …