[PDF][PDF] Doctorado en Ingeniería, Mención Procesamiento de Señales e Imágenes

MIM Namías - 2020 - researchgate.net
La cuantificación en PET se ve afectada por diversos factores técnicos y físicos durante las
etapas de adquisición de la imagen, postproceso (filtrado), y análisis de las imágenes (ej …

A novel approach for quantitative harmonization in PET

M Namias, T Bradshaw, VO Menezes… - Physics in Medicine …, 2018 - iopscience.iop.org
Positron emission tomography (PET) imaging allows for measurement of activity
concentrations of a given radiotracer in vivo. The quantitative capabilities of PET imaging …

Towards task-based assessment of PET performance: System and object DQE across different reconstruction algorithms

A Samartzis, G Fountos, GA Kastis, E Kounadi… - Physica Medica, 2016 - Elsevier
Introduction Detective quantum efficiency (DQE) of an imaging system is an indicator of the
image quality metrics of the system taking into consideration detector efficiency. Purpose To …

Impact of tomographic reconstruction with Bayesian penalty in the quantification of PET/CT studies

G Reynés-Llompart - 2020 - dadun.unav.edu
Additionally, it is also necessary for all tests using ionizing radiation to be performed with the
lowest possible radiation dose to the patient, compatible with the necessary diagnostic …

Detector design and optimization for a small animal PET and characterization of its system response

ENG Navarro - 2008 - dialnet.unirioja.es
Introducción El campo dedicado a la imagen médica comprende todos aquellos
procedimientos científico-tecnológicos que permiten visualizar la estructura o el …

Factors affecting quantification in PET/CT imaging

O Mawlawi, SC Kappadath, T Pan… - Current Medical …, 2008 - ingentaconnect.com
In the past few years, PET and PET/CT imaging have increasingly been used as the
modalities of choice for the diagnosis, staging and restaging of malignant disease. The main …

[HTML][HTML] Evaluación de los factores metodológicos que afectan la cuantificación de imágenes de PET/CT

JM Ferreyra - 2011 - ricabib.cab.cnea.gov.ar
La utilización del PET/CT con [18” F] fluoro-2-deoxy-D-glucosa (FDG) ha sido reconocida
como una importante herramienta clínica, particularmente en oncología, para el diagnóstico …

Evaluation of a Method Combining Physical Experiment and Data Insertion For the Assessment of PET-CT Systems

Q Maronnier, F Courbon, O Caselles - 2021 - researchsquare.com
Background: To evaluate and compare Positron Emission Tomography (PET) devices
among them, tests are performed on phantoms that generally consist in simple geometrical …

[PDF][PDF] Caracterización, mejora y diseño de escáneres PET preclínicos

EV Torrico - Madri: Universidad Complutense de Madrid, 2012 - docta.ucm.es
Positron Emission Tomography (PET)[Cherry et al., 2003] is a nuclear medicine technique
that uses radioactive substances for the diagnosis and staging of different diseases. These …

Caracterización, mejora y diseño de escáneres PET preclínicos

E Vicente Torrico - 2013 - docta.ucm.es
Positron Emission Tomography (PET)[Cherry et al., 2003] is a nuclear medicine technique
that uses radioactive substances for the diagnosis and staging of different diseases. These …