Saturation recovery single‐shot acquisition (SASHA) for myocardial T1 mapping
K Chow, JA Flewitt, JD Green… - Magnetic resonance …, 2014 - Wiley Online Library
Purpose To validate a new saturation recovery single‐shot acquisition (SASHA) pulse
sequence for T1 mapping and to compare SASHA T1 values in heart failure patients and …
sequence for T1 mapping and to compare SASHA T1 values in heart failure patients and …
Myocardial T1-mapping at 3T using saturation-recovery: reference values, precision and comparison with MOLLI
Background Myocardial T 1-mapping recently emerged as a promising quantitative method
for non-invasive tissue characterization in numerous cardiomyopathies. Commonly …
for non-invasive tissue characterization in numerous cardiomyopathies. Commonly …
Joint myocardial T1 and T2 mapping using a combination of saturation recovery and T2‐preparation
Purpose To develop a heart‐rate independent breath‐held joint T1–T2 mapping sequence
for accurate simultaneous estimation of coregistered myocardial T1 and T2 maps. Methods …
for accurate simultaneous estimation of coregistered myocardial T1 and T2 maps. Methods …
Systolic ShMOLLI myocardial T1-mapping for improved robustness to partial-volume effects and applications in tachyarrhythmias
VM Ferreira, RS Wijesurendra, A Liu, A Greiser… - Journal of …, 2015 - Springer
Background T1-mapping using the Shortened Modified Look-Locker Inversion Recovery
(ShMOLLI) technique enables non-invasive assessment of important myocardial tissue …
(ShMOLLI) technique enables non-invasive assessment of important myocardial tissue …
T1 measurements in the human myocardium: The effects of magnetization transfer on the SASHA and MOLLI sequences
MD Robson, SK Piechnik… - Magnetic resonance …, 2013 - Wiley Online Library
Purpose Quantitative mapping of the native T1 of the heart using the modified look‐locker
inversion recovery (MOLLI) technique provides high quality diagnostic information without …
inversion recovery (MOLLI) technique provides high quality diagnostic information without …
[HTML][HTML] Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold
SK Piechnik, VM Ferreira, E Dall'Armellina… - Journal of …, 2010 - Elsevier
Background T1 mapping allows direct in-vivo quantitation of microscopic changes in the
myocardium, providing new diagnostic insights into cardiac disease. Existing methods …
myocardium, providing new diagnostic insights into cardiac disease. Existing methods …
Free‐breathing multislice native myocardial T1 mapping using the slice‐interleaved T1 (STONE) sequence
Purpose To develop a novel pulse sequence for free‐breathing, multislice, native
myocardial T1 mapping. Methods The slice‐interleaved T1 (STONE) sequence consists of …
myocardial T1 mapping. Methods The slice‐interleaved T1 (STONE) sequence consists of …
Free‐running 3D whole heart myocardial T1 mapping with isotropic spatial resolution
Purpose To develop a free‐running (free‐breathing, retrospective cardiac gating) 3D
myocardial T1 mapping with isotropic spatial resolution. Methods The free‐running …
myocardial T1 mapping with isotropic spatial resolution. Methods The free‐running …
Free‐breathing, non‐ECG, continuous myocardial T1 mapping with cardiovascular magnetic resonance multitasking
Purpose To evaluate the accuracy and repeatability of a free‐breathing, non‐
electrocardiogram (ECG), continuous myocardial T1 and extracellular volume (ECV) …
electrocardiogram (ECG), continuous myocardial T1 and extracellular volume (ECV) …
Accelerated cardiac T2 mapping using breath‐hold multiecho fast spin‐echo pulse sequence with k‐t FOCUSS
Cardiac T2 mapping is a promising method for quantitative assessment of myocardial
edema and iron overload. We have developed a new multiecho fast spin echo (ME‐FSE) …
edema and iron overload. We have developed a new multiecho fast spin echo (ME‐FSE) …