Analysis of a pulse rate variability measurement using a smartphone camera

A Bánhalmi, J Borbás, M Fidrich… - Journal of healthcare …, 2018 - Wiley Online Library
Background. Heart rate variability (HRV) provides information about the activity of the
autonomic nervous system. Because of the small amount of data collected, the importance of …

Measurement of heart rate variability using off-the-shelf smart phones

RY Huang, LR Dung - Biomedical engineering online, 2016 - Springer
Background The cardiac parameters, such as heart rate (HR) and heart rate variability
(HRV), are very important physiological data for daily healthcare. Recently, the camera …

[HTML][HTML] The minimal sampling frequency of the photoplethysmogram for accurate pulse rate variability parameters in healthy volunteers

S Béres, L Hejjel - Biomedical Signal Processing and Control, 2021 - Elsevier
Objective Today mobile health-monitoring devices calculate heart rate and its variability
mostly from the photoplethysmogram (PPG). Minimizing the power consumption is crucial …

Photoplethysmography sampling frequency: pilot assessment of how low can we go to analyze pulse rate variability with reliability?

A Choi, H Shin - Physiological measurement, 2017 - iopscience.iop.org
Pulse rate variability (PRV) analysis appears as the first alternative to heart rate variability
analysis for wearable devices; however, there is a constraint on computational load and …

Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography

N Selvaraj, A Jaryal, J Santhosh… - Journal of medical …, 2008 - Taylor & Francis
Heart rate variability (HRV) is traditionally derived from RR interval time series of
electrocardiography (ECG). Photoplethysmography (PPG) also reflects the cardiac rhythm …

A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects

G Lu, F Yang, JA Taylor, JF Stein - Journal of medical engineering …, 2009 - Taylor & Francis
Measures of heart rate variability (HRV) are widely used to assess autonomic nervous
system (ANS) function. The signal from which they are derived requires accurate …

Design and prototyping of a wristband-type wireless photoplethysmographic device for heart rate variability signal analysis

M Ghamari, C Soltanpur, S Cabrera… - 2016 38th Annual …, 2016 - ieeexplore.ieee.org
Heart Rate Variability (HRV) signal analysis provides a quantitative marker of the Autonomic
Nervous System (ANS) function. A wristband-type wireless photoplethysmographic (PPG) …

Comparison of heart rate variability from PPG with that from ECG

WH Lin, D Wu, C Li, H Zhang, YT Zhang - … 2013, Vilamoura, Portugal on 7-9 …, 2014 - Springer
Because it is more convenient to measure photoplethysmography (PPG) than ECG, PPG is
supposed as a surrogate of ECG for heart rate variability (HRV) analysis. In this study, we …

Extraction of heart rate variability from smartphone photoplethysmograms

RC Peng, XL Zhou, WH Lin… - … mathematical methods in …, 2015 - Wiley Online Library
Heart rate variability (HRV) is a useful clinical tool for autonomic function assessment and
cardiovascular diseases diagnosis. It is traditionally calculated from a dedicated medical …

A photoplethysmography smartphone-based method for heart rate variability assessment: Device model and breathing influences

F Guede-Fernández, V Ferrer-Mileo… - … Signal Processing and …, 2020 - Elsevier
A measurement method of heart rate and heart rate variability (HRV) based on smartphone
has been developed and validated. The method is based on photoplethysmography (PPG) …