Analysis of a pulse rate variability measurement using a smartphone camera
A Bánhalmi, J Borbás, M Fidrich… - Journal of healthcare …, 2018 - Wiley Online Library
Background. Heart rate variability (HRV) provides information about the activity of the
autonomic nervous system. Because of the small amount of data collected, the importance of …
autonomic nervous system. Because of the small amount of data collected, the importance of …
Measurement of heart rate variability using off-the-shelf smart phones
RY Huang, LR Dung - Biomedical engineering online, 2016 - Springer
Background The cardiac parameters, such as heart rate (HR) and heart rate variability
(HRV), are very important physiological data for daily healthcare. Recently, the camera …
(HRV), are very important physiological data for daily healthcare. Recently, the camera …
[HTML][HTML] The minimal sampling frequency of the photoplethysmogram for accurate pulse rate variability parameters in healthy volunteers
Objective Today mobile health-monitoring devices calculate heart rate and its variability
mostly from the photoplethysmogram (PPG). Minimizing the power consumption is crucial …
mostly from the photoplethysmogram (PPG). Minimizing the power consumption is crucial …
Photoplethysmography sampling frequency: pilot assessment of how low can we go to analyze pulse rate variability with reliability?
Pulse rate variability (PRV) analysis appears as the first alternative to heart rate variability
analysis for wearable devices; however, there is a constraint on computational load and …
analysis for wearable devices; however, there is a constraint on computational load and …
Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography
N Selvaraj, A Jaryal, J Santhosh… - Journal of medical …, 2008 - Taylor & Francis
Heart rate variability (HRV) is traditionally derived from RR interval time series of
electrocardiography (ECG). Photoplethysmography (PPG) also reflects the cardiac rhythm …
electrocardiography (ECG). Photoplethysmography (PPG) also reflects the cardiac rhythm …
A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects
G Lu, F Yang, JA Taylor, JF Stein - Journal of medical engineering …, 2009 - Taylor & Francis
Measures of heart rate variability (HRV) are widely used to assess autonomic nervous
system (ANS) function. The signal from which they are derived requires accurate …
system (ANS) function. The signal from which they are derived requires accurate …
Design and prototyping of a wristband-type wireless photoplethysmographic device for heart rate variability signal analysis
M Ghamari, C Soltanpur, S Cabrera… - 2016 38th Annual …, 2016 - ieeexplore.ieee.org
Heart Rate Variability (HRV) signal analysis provides a quantitative marker of the Autonomic
Nervous System (ANS) function. A wristband-type wireless photoplethysmographic (PPG) …
Nervous System (ANS) function. A wristband-type wireless photoplethysmographic (PPG) …
Comparison of heart rate variability from PPG with that from ECG
Because it is more convenient to measure photoplethysmography (PPG) than ECG, PPG is
supposed as a surrogate of ECG for heart rate variability (HRV) analysis. In this study, we …
supposed as a surrogate of ECG for heart rate variability (HRV) analysis. In this study, we …
Extraction of heart rate variability from smartphone photoplethysmograms
RC Peng, XL Zhou, WH Lin… - … mathematical methods in …, 2015 - Wiley Online Library
Heart rate variability (HRV) is a useful clinical tool for autonomic function assessment and
cardiovascular diseases diagnosis. It is traditionally calculated from a dedicated medical …
cardiovascular diseases diagnosis. It is traditionally calculated from a dedicated medical …
A photoplethysmography smartphone-based method for heart rate variability assessment: Device model and breathing influences
F Guede-Fernández, V Ferrer-Mileo… - … Signal Processing and …, 2020 - Elsevier
A measurement method of heart rate and heart rate variability (HRV) based on smartphone
has been developed and validated. The method is based on photoplethysmography (PPG) …
has been developed and validated. The method is based on photoplethysmography (PPG) …