Lung volume assessments in normal and surfactant depleted lungs: agreement between bedside techniques and CT imaging

G Albu, F Petak, T Zand, M Hallbäck, M Wallin… - BMC …, 2014 - Springer
Background Bedside assessment of lung volume in clinical practice is crucial to adapt
ventilation strategy. We compared bedside measures of lung volume by helium multiple …

Comparison of static end-expiratory and effective lung volumes for gas exchange in healthy and surfactant-depleted lungs

G Albu, M Wallin, M Hallbäck, P Emtell, A Wolf… - …, 2013 - pubs.asahq.org
Background: Effective lung volume (ELV) for gas exchange is a new measure that could be
used as a real-time guide during controlled mechanical ventilation. The authors established …

PEEP decreases atelectasis and extravascular lung water but not lung tissue volume in surfactant-washout lung injury

T Luecke, H Roth, P Herrmann, A Joachim… - Intensive care …, 2003 - Springer
Objective To examine the effects of positive end-expiratory pressure (PEEP) on
extravascular lung water (EVLW), lung tissue, and lung volume. Design and setting …

Reliability of the nitrogen washin-washout technique to assess end-expiratory lung volume at variable PEEP and tidal volumes

JC Richard, C Pouzot, AM Pinzón… - Intensive care medicine …, 2014 - Springer
Background End-expiratory lung volume measurement by the nitrogen washin-washout
technique (EELV WI-WO) may help titrating positive end-expiratory pressure (PEEP) during …

Alveolar volume determined by single-breath helium dilution correlates with the high-resolution computed tomography-derived nonemphysematous lung volume

I Van der Lee, HW Van Es, HJ Noordmans… - Respiration, 2006 - karger.com
Background: The alveolar volume (VA), determined by single-breath helium dilution, is a
measure for the total lung capacity (TLC) that is very sensitive to ventilatory disturbances. In …

The effect of alveolar dead space on the measurement of end-expiratory lung volume by modified nitrogen wash-out/wash-in in lavage-induced lung injury

R Tang, Y Huang, Q Chen, X Hui, Y Li, Q Yu… - Respiratory …, 2012 - rc.rcjournal.com
BACKGROUND: The accuracy of end-expiratory lung volume measurement by the modified
nitrogen wash-out/wash-in method (EELV-N2) depends on the precise determination of …

Lung volume in mechanically ventilated patients: measurement by simplified helium dilution compared to quantitative CT scan

N Patroniti, G Bellani, A Manfio, E Maggioni… - Intensive care …, 2004 - Springer
Objective We describe a simplified helium dilution technique to measure end-expiratory lung
volume (EELV) in mechanically ventilated patients. We assessed both its accuracy in …

Radiographic lung density assessed by computed tomography is associated with extravascular lung water content

VV Kuzkov, EV Suborov, MY Kirov… - Acta …, 2010 - Wiley Online Library
Background: We hypothesized that in acute lung injury (ALI), the volume of pulmonary tissue
with aqueous density, as determined by spiral computed tomography (CT), is associated …

Accuracy of the end-expiratory lung volume measured by the modified nitrogen washout/washin technique: a bench study

J Berger-Estilita, M Haenggi, D Ott, D Berger - Journal of translational …, 2021 - Springer
Background The functional residual capacity (FRC) determines the oxygenating capacity of
the lung and is heavily affected in the clinical context of the acute respiratory distress …

Clinical and experimental validation of a capnodynamic method for end‐expiratory lung volume assessment

T Öhman, TS Sigmundsson, M Hallbäck… - Acta …, 2020 - Wiley Online Library
Introduction Lung protective ventilation can decrease post‐operative pulmonary
complications. The aim of this study was to evaluate a capnodynamic method estimating …