A Hand-Held Indentation System for the Assessment of Mechanical Properties of Soft Tissues In Vivo

MH Lu, W Yu, QH Huang, YP Huang… - IEEE Transactions on …, 2009 - ieeexplore.ieee.org
Quantitative assessment of the mechanical properties of soft tissues in vivo is required in
both clinical and research fields. This paper introduces a hand-held indentation system that …

Extraction of effective Young's modulus of skin and subcutaneous tissues from manual indentation data

YP Zheng, AFT Mak - … Conference of the IEEE Engineering in …, 1997 - ieeexplore.ieee.org
An ultrasound indentation system with a pen-size hand-held probe was used to obtain the
indentation responses of forearm soft tissues. Three normal forearms were each tested with …

[HTML][HTML] Experimental validation of a flat punch indentation methodology calibrated against unconfined compression tests for determination of soft tissue biomechanics

RM Delaine-Smith, S Burney, FR Balkwill… - Journal of the mechanical …, 2016 - Elsevier
Mechanical characterisation of soft biological tissues using standard compression or tensile
testing presents a significant challenge due to specimen geometrical irregularities …

Objective assessment of limb tissue elasticity: development of a manual indentation procedure

YP Zheng, AFT Mak, B Lue - Journal of rehabilitation research …, 1999 - ira.lib.polyu.edu.hk
An ultrasound indentation system with a pen-size hand-held probe was developed and used
to obtain the effective Young's moduli of forearm and lower limb soft tissues in 12 subjects …

Accuracy and reliability testing of a portable soft tissue indentor

JW Klaesner, PK Commean… - … on Neural Systems …, 2001 - ieeexplore.ieee.org
We have designed, built, and tested a portable indentor device that allows us to determine
force/displacement (F/D) measurements on soft tissue in a clinical or research setting. The …

Experimental and computational analysis of soft tissue stiffness in forearm using a manual indentation device

JT Iivarinen, RK Korhonen, P Julkunen… - Medical engineering & …, 2011 - Elsevier
A hand held stiffness meter can be used to measure indentation stiffness of human soft
tissues, sensitively altered, eg, by pathological tissue swelling. Under indentation load, the …

Effective elastic properties for lower limb soft tissues from manual indentation experiment

Y Zheng, AFT Mak - IEEE Transactions on rehabilitation …, 1999 - ieeexplore.ieee.org
Quantitative assessment of the biomechanical properties of limb soft tissues has become
more important during the last decade because of the introduction of computer-aided design …

Indentation test of soft tissues with curved substrates: a finite element study

MH Lu, YP Zheng - Medical and Biological Engineering and Computing, 2004 - Springer
Indentation is a commonly used approach to measure the mechanical properties of soft
tissues, such as articular cartilage and limb tissues. The Young's modulus of tissue can be …

Experimental and numerical analysis of soft tissue stiffness measurement using manual indentation device–significance of indentation geometry and soft tissue …

JT Iivarinen, RK Korhonen… - Skin Research and …, 2014 - Wiley Online Library
Background Indentation techniques haves been applied to measure stiffness of human soft
tissues. Tissue properties and geometry of the indentation instrument control the measured …

Viscoelasticity measurement of softness by indentation devices for evaluation of human skin

A Sakuma, Y Sango - … Engineering Congress and …, 2014 - asmedigitalcollection.asme.org
In this paper, spherical indentation testing is studied to evaluate the viscoelasticity of soft
materials like human skin. Here, the Hertzian contact theory is functionally extended to …