Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the …
BL Wilkoff, BD Williamson, RS Stern, SL Moore… - Journal of the American …, 2008 - jacc.org
Objectives: Our purpose was to demonstrate that strategically chosen implantable
cardioverter-defibrillator (ICD) ventricular tachycardia (VT) or ventricular fibrillation (VF) …
cardioverter-defibrillator (ICD) ventricular tachycardia (VT) or ventricular fibrillation (VF) …
Programming implantable cardioverter‐defibrillators in patients with primary prevention indication to prolong time to first shock: results from the PROVIDE study
M Saeed, I Hanna, D Robotis… - Journal of …, 2014 - Wiley Online Library
ICD Programming for Shock Reduction Background Shock therapy delivery by implantable
cardioverter‐defibrillators (ICD) can be painful and may have adverse consequences …
cardioverter‐defibrillators (ICD) can be painful and may have adverse consequences …
A comparison of empiric to physician-tailored programming of implantable cardioverter-defibrillators: results from the prospective randomized multicenter EMPIRIC …
BL Wilkoff, KT Ousdigian, LD Sterns, ZJ Wang… - Journal of the American …, 2006 - jacc.org
Objectives: The purpose of this randomized study was to determine whether a strategically
chosen standardized set of programmable settings is at least as effective as physician …
chosen standardized set of programmable settings is at least as effective as physician …
Appropriate and inappropriate ventricular therapies, quality of life, and mortality among primary and secondary prevention implantable cardioverter defibrillator …
MO Sweeney, MS Wathen, K Volosin, I Abdalla… - Circulation, 2005 - Am Heart Assoc
Background—Implantable cardioverter defibrillators (ICDs) reduce mortality in primary and
secondary prevention. Quality of life, mortality, appropriate therapies for specific ventricular …
secondary prevention. Quality of life, mortality, appropriate therapies for specific ventricular …
Reduction in inappropriate therapy and mortality through ICD programming
AJ Moss, C Schuger, CA Beck, MW Brown… - … England Journal of …, 2012 - Mass Medical Soc
Background The implantable cardioverter–defibrillator (ICD) is highly effective in reducing
mortality among patients at risk for fatal arrhythmias, but inappropriate ICD activations are …
mortality among patients at risk for fatal arrhythmias, but inappropriate ICD activations are …
Impact of programming strategies aimed at reducing nonessential implantable cardioverter defibrillator therapies on mortality: a systematic review and meta-analysis
Background—Patients who receive implantable cardioverter defibrillator therapies are at
higher risk of death versus those who do not. Programmed settings to reduce nonessential …
higher risk of death versus those who do not. Programmed settings to reduce nonessential …
[HTML][HTML] Low inappropriate shock rates in patients with single-and dual/triple-chamber implantable cardioverter-defibrillators using a novel suite of detection algorithms …
A Auricchio, EJ Schloss, T Kurita, A Meijer, B Gerritse… - Heart Rhythm, 2015 - Elsevier
Background The benefits of implantable cardioverter-defibrillators (ICDs) have been well
demonstrated in many clinical trials, and ICD shocks for ventricular tachyarrhythmias save …
demonstrated in many clinical trials, and ICD shocks for ventricular tachyarrhythmias save …
Randomized controlled study of detection enhancements versus rate-only detection to prevent inappropriate therapy in a dual-chamber implantable cardioverter …
P Dorian, F Philippon, B Thibault, S Kimber, L Sterns… - Heart Rhythm, 2004 - Elsevier
OBJECTIVES: The purpose of this study was to compare rate-only detection to enhanced
detection in a dual-chamber implantable cardioverter-defibrillator (ICD), to discriminate …
detection in a dual-chamber implantable cardioverter-defibrillator (ICD), to discriminate …
A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure …
M Gasparini, C Menozzi, A Proclemer… - European heart …, 2009 - academic.oup.com
Aims To investigate the efficacy and safety of a cardiac resynchronization therapy with
cardioverter–defibrillator (CRT-D) device with simplified ventricular tachycardia …
cardioverter–defibrillator (CRT-D) device with simplified ventricular tachycardia …
Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery: the ADVANCE III …
M Gasparini, A Proclemer, C Klersy, A Kloppe, M Lunati… - Jama, 2013 - jamanetwork.com
Importance Using more intervals to detect ventricular tachyarrhythmias has been associated
with reducing unnecessary implantable cardioverter-defibrillator (ICD) therapies. Objective …
with reducing unnecessary implantable cardioverter-defibrillator (ICD) therapies. Objective …