Type E2 glenoid bone loss orientation and management with augmented implants

S Abdic, NK Knowles, G Walch, JA Johnson… - Journal of Shoulder and …, 2020 - Elsevier
Background The purpose of this study was 2-fold:(1) to quantify type E2 bone loss
orientation and its association with rotator cuff fatty infiltration and (2) to examine reverse …

The effect of glenohumeral radial mismatch on different augmented total shoulder arthroplasty glenoid designs: a finite element analysis

VJ Sabesan, DJL Lima, JD Whaley, V Pathak… - Journal of Shoulder and …, 2019 - Elsevier
Background Augmented glenoid implants to correct bone loss can possibly reconcile current
prosthetic failures and improve long-term performance for total shoulder arthroplasty …

Posterior augmented glenoid implants require less bone removal and generate lower stresses: a finite element analysis

JJ Allred, C Flores-Hernandez, HR Hoenecke Jr… - Journal of Shoulder and …, 2016 - Elsevier
Hypothesis Glenoid retroversion can be corrected with standard glenoid implants after
anterior-side asymmetric reaming or by using posterior augmented glenoid implants with …

Posterior augmented glenoid designs preserve more bone in biconcave glenoids

AD Kersten, C Flores-Hernandez, HR Hoenecke… - Journal of Shoulder and …, 2015 - Elsevier
Background and hypothesis Total shoulder arthroplasty is recommended treatment for
severe osteoarthritis of the glenohumeral joint, which often results in excessive posterior …

Biomechanical comparison of 2 augmented glenoid designs: an integrated kinematic finite element analysis

VJ Sabesan, DJL Lima, JD Whaley, V Pathak… - Journal of shoulder and …, 2019 - Elsevier
Background Augmented glenoid implants are available to help restore the biomechanics of
the glenohumeral joint with excessive retroversion. It is imperative to understand their …

Augmented glenoid component designs for type B2 erosions: a computational comparison by volume of bone removal and quality of remaining bone

NK Knowles, LM Ferreira, GS Athwal - Journal of shoulder and elbow …, 2015 - Elsevier
Background The purpose of this computational modeling study was to compare the volume
of glenoid bone removal required to implant 3 augmented component designs for …

Augmented glenoid implants in anatomic total shoulder arthroplasty: review of available implants and current literature

M Ghoraishian, JA Abboud, AA Romeo… - Journal of Shoulder and …, 2019 - Elsevier
Glenoid bone loss and retroversion increase the complexity of primary shoulder arthroplasty
and affect the outcome. Although eccentric reaming, augmented glenoid implants, bone …

How much bone support does an anatomic glenoid component need?

F Verhaegen, E Campopiano, P Debeer… - Journal of shoulder and …, 2020 - Elsevier
Background An important reason for failure of anatomic total shoulder arthroplasty is glenoid
component loosening. We investigated the effect of backside bone support on the risk of …

Early results of augmented anatomic glenoid components

M Priddy, A Zarezadeh, KW Farmer, AM Struk… - Journal of Shoulder and …, 2019 - Elsevier
Background Augmented glenoid components restore the native joint line and preserve bone
in shoulders with posterior glenoid bone loss. The purpose of this study was to compare the …

Optimizing glenoid component position using three-dimensional computed tomography reconstruction

HR Hoenecke Jr, JC Hermida, N Dembitsky… - Journal of shoulder and …, 2008 - Elsevier
Glenoid implant design and alignment are critical to the success of shoulder arthroplasty.
Computer-aided design models of 3 glenoid implant designs (keel, standard pegs, and …