Empirical model of the photon path length for a single fiber reflectance spectroscopy device

SC Kanick, H Sterenborg, A Amelink - Optics express, 2009 - opg.optica.org
A reflectance spectroscopic device that utilizes a single fiber for both light delivery and
collection has advantages over classical multi-fiber probes. This study presents a novel …

Accurate extraction of optical properties and top layer thickness of two-layered mucosal tissue phantoms from spatially resolved reflectance spectra

KB Sung, KW Shih, FW Hsu, HP Hsieh… - … of biomedical optics, 2014 - spiedigitallibrary.org
We are reporting on an experimental investigation of a movable diffuse reflectance
spectroscopy system to extract diagnostically relevant optical properties of two-layered …

Limitations of the commonly used simplified laterally uniform optical fiber probe-tissue interface in Monte Carlo simulations of diffuse reflectance

P Naglič, F Pernuš, B Likar, M Bürmen - Biomedical optics express, 2015 - opg.optica.org
Light propagation models often simplify the interface between the optical fiber probe tip and
tissue to a laterally uniform boundary with mismatched refractive indices. Such simplification …

Analysis of changes in reflectance measurements on biological tissues subjected to different probe pressures

R Reif, MS Amorosino, KW Calabro… - … of biomedical optics, 2008 - spiedigitallibrary.org
Spectral reflectance measurements of biological tissues have been studied for early
diagnoses of several pathologies such as cancer. These measurements are often performed …

Instrument independent diffuse reflectance spectroscopy

B Yu, HL Fu, N Ramanujam - Journal of Biomedical Optics, 2011 - spiedigitallibrary.org
Diffuse reflectance spectroscopy with a fiber optic probe is a powerful tool for quantitative
tissue characterization and disease diagnosis. Significant systematic errors can arise in the …

Comparison of spectral variation from spectroscopy to spectral imaging

SC Gebhart, SK Majumder, A Mahadevan-Jansen - Applied optics, 2007 - opg.optica.org
Optical biopsy has been shown to discriminate between normal and diseased tissue with
high sensitivity and specificity. Fiber-optic probe-based spectroscopy systems do not provide …

Diffuse reflectance spectroscopy with a self-calibrating fiber optic probe

B Yu, H Fu, T Bydlon, JE Bender, N Ramanujam - Optics letters, 2008 - opg.optica.org
Calibration of the diffuse reflectance spectrum for instrument response and time-dependent
fluctuation as well as interdevice variations is complicated, time consuming, and potentially …

Fiber optic probe for polarized reflectance spectroscopy in vivo: Design and performance

A Myakov, L Nieman, L Wicky… - … of biomedical optics, 2002 - spiedigitallibrary.org
We present the design and construction of a fiber optic probe for elastic light scattering
spectroscopy in vivo with polarized excitation and polarization sensitive detection. The …

Method for rapid multidiameter single-fiber reflectance and fluorescence spectroscopy through a fiber bundle

CL Hoy, UA Gamm, HJCM Sterenborg… - … of biomedical optics, 2013 - spiedigitallibrary.org
We have recently demonstrated a means for quantifying the absorption and scattering
properties of biological tissue through multidiameter single-fiber reflectance (MDSFR) …

Experimental validation of Monte Carlo modeling of fluorescence in tissues in the UV-visible spectrum

Q Liu, C Zhu, N Ramanujam - Journal of biomedical optics, 2003 - spiedigitallibrary.org
The goal of the work is to experimentally verify Monte Carlo modeling of fluorescence and
diffuse reflectance measurements in turbid, tissue phantom models. In particular, two series …